7
Installation
Installation Requirements
NOTE:
•
It is most important that this appliance is installed correctly and that operation is
correct before use. Installation shall comply with local, gas, health and safety
requirements.
•
This appliance shall be installed with sufficient ventilation to prevent the occurrence
of unacceptable concentrations of health harmful substances in the room, the
appliance is installed in.
Blue Seal ‘FAST FRI’ gas fryers are designed to provide years of satisfactory service and correct installation
is essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas and fire safety.
Australia:
AS 5601
- Gas Installations.
New Zealand:
NZS 5261
- Gas Installation.
United Kingdom:
Gas Safety (Installation and Use) Regulations 1998.
Ireland:
IS 820
- Non Domestic Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install
equipment to the relevant codes and manufacturer’s specifications shown in this section will
void the warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer, are only
allowed to be adjusted by an authorised service agent. They are not to be adjusted by the
installation person.
Unpacking
•
Remove all packaging and transit protection from the appliance including all protective plastic
coating from the door outer panel and exterior stainless steel panels.
•
Check equipment and parts for damage. Report any damage immediately to the carrier and
distributor.
•
Report any deficiencies to the distributor who supplied the appliance.
•
Check that the available gas supply is correct to that shown on the rating plate located on the inside
of the access door.
•
Check that the following parts have been supplied with the appliance:
GT45
GT46
GT60
Baskets 2
2
3
Basket Trays
1
2
1
Lid 1
1
1
Drain Stick
1
1
1
Location
1.
This appliance must be installed in a suitably ventilated room to prevent dangerous build up of
combustion products.
2.
Installation must allow for a sufficient flow of fresh air for the combustion air supply.
Combustion Air Requirements
Natural Gas
24 m³/hr minimum.
LPG / Propane
24 m³/hr minimum.
3.
Position the appliance in its approximate working position.