-29-
Revision 5/F3534
©
Moffat Ltd, April 2005
Turbofan Convection Oven
Two Screws
6.3 REPLACEMENT
6.3.1 LIGHT BULB / GLASS
6.3.2 DOOR MICROSWITCH
1) Unscrew lamp cover.
1) Remove service panel (refer 6.2.2).
2) Remove two screws holding microswitch to
bracket.
6.3.3 INDICATOR NEON LIGHT
1) With control panel open (refer 6.2.1) remove
the wires from the back of the neon.
6.3.4 POWER / ROAST / LIGHTS / WATER
SWITCHES
1) With control panel open (refer 6.2.1)
remove the wires from the back of the switch,
noting their positions.
2) Unscrew bulb out of fitting.
3) Screw in replacement bulb.
4) Ensure seal fitted. Screw lamp cover into
holder with baffle fitted (do not over tighten).
Lamp
Cover
Figure 6.3.1
3) Transfer wires to new micro-switch and
re-assemble.
4) Adjust microswitch (refer 6.4.2).
Figure 6.3.2
2) From back push neon through front of panel
rotating clockwise.
3) Push new neon in from front of panel, and
reconnect wires.
2) From back push switch through front of panel.
3) Push new switch in from front of panel, and
reconnect wires.
Neon
Wires
Switch
Wires
Figure 6.3.3
Figure 6.3.4
6.3.5 POWER RELAY (FROM S/N 232054)
1) Remove service panel (refer 6.2.2).
2) Remove the two screws securing the relay to
the rear panel.
3) Transfer the wires to the new relay.
4) Secure the relay to the rear panel with two
screws and replace the service panel.
Power
Relay
Figure 6.3.5