-56-
Revision 5/F3534
©
Moffat Ltd, April 2005
Turbofan Convection Oven
Power switch
Mini-contactor
Kit (part no. 024563) includes:
1
x
Power
relay
2
x
Screw - 8 x
3
/
8
truss
1
x
160mm black wire
1
x
180mm red wire
1
x
950mm red wire
1
x
1050 red wire
Assembly Instructions:
(THE ELECTRICAL SUPPLY MUST BE DISCONNECTED)
1) Remove the rear service panel.
2) Mark and drill 2x ø3.5mm holes as per figure 1.
3) Mount relay to holes with 2 screws provided.
(
NOTE:
Terminals on relay must face
upwards).
4) Connect 160mm black wire to vacant neutral
(L2) terminal on terminal block and to terminal
B on relay.
5) Connect short (180mm) red wire to vacant
phase (L1) terminal on terminal block and to
terminal 7 on relay.
6) Connect long thick red wire (950mm) to power
relay terminal 4 and remaining long thin wire
(1050mm) to relay terminal A. Feed these
wires through the plastic bush in the rear of the
oven and into the control cavity.
7) Loosen screws and open the control panel.
8) Remove and discard wire from terminal 2 on
the power switch to terminal 21 on the mini
contactor inside the control panel.
Locate end of thick red wire previously fed into
control cavity and connect to terminal 21 of the
contactor.
9) Locate long thin red wire and connect to
terminal 2 on the power switch.
10) Close and fasten control panel taking care not
to trap any wires.
11) Replace and fasten rear service panel.
Figure 1
Figure 2
64
85
185
APPENDIX A. POWER RELAY UPGRADE KIT