C-1000A Iridium™ Satellite Phone System
100115
Wire Harness Fabrication & Installation Considerations
Referring to the appropriate section of this manual, assemble a wiring harness as
required for the installation. All wires must be MIL-SPEC in accordance with current
regulations. Two-conductor shielded wire must be used where indicated and be MIL-
C-27500 or equivalent specification. Shields should only be grounded at the Modem
Unit end of the interconnect cable. Other ends remain floating.
It is imperative that the correct wiring be used and that proper stripping, shielding,
grounding, crimping and soldering techniques be used at all times. Failure to correct
techniques may result in poor performance, electrical noise or unit failure.
Power Wiring
To assure that the C-1000A will operate properly down to its rated minimum input
voltage, ensure that power wires of at least the recommended size are connected in
accordance with the installation drawings. It is recommended that power and ground
wires are a twisted pair to reduce signal noise.
Ground Bonding
In order to assure installation characteristics match the DO-160 RF and Lightning
test conditions, ensure that ground wires of at least the recommended size are
installed and these wires are connected to a bonded aircraft ground.
Note:
Both the Modem Unit and the Cabin Unit need to be grounded to the airframe
for proper operation. See Pinout tables for correct pin information.
Cable & Wire Harness Routing Considerations
The length and routing of cables must be carefully planned before starting the
installation.
Avoid sharp bends in the cable.
Do not locate the cable near aircraft controls.
Observe all appropriate sections of FAR Parts 23, 25, 27, and 29, as well as AC
43.13-1B and AC 43.13-2A. Damage caused by improper installation will void
product warranty.
In order to ensure optimum performance, the C-1000A and associated wiring
should be kept a minimum of three feet from high noise sources and not routed
with cables from high power sources.
Summary of Contents for Iridium C-1000A
Page 37: ...December 2006 Blue Sky Network 100115 C 1000A Iridium Satellite Phone System Page 33 ...
Page 38: ...Page 34 C 1000A Iridium Satellite Phone System 100115 ...
Page 43: ...December 2006 Blue Sky Network 100115 C 1000A Iridium Satellite Phone System Page 39 ...
Page 44: ...Page 40 C 1000A Iridium Satellite Phone System 100115 ...
Page 45: ...December 2006 Blue Sky Network 100115 C 1000A Iridium Satellite Phone System Page 41 ...