Blue Sky Energy - Solar Boost 1524iX
SYMPTOM
PROBABLE CAUSE
ITEMS TO EXAMINE OR CORRECT
Networked units do not
seem to coordinate
action or slaves do not
turn on
IPN network address set wrong
Network wiring problem
One unit of a multi-unit network must be set to IPN network address 0 (zero), AND all other units
must be set to different addresses.
Confirm wiring correctly in place. Use IPN-ProRemote to view Charge Unit Status screens to
confirm communication.
Temperature related
functions do not work.
Temperature sensor not installed on master
Temperature sensor failed or installed
reverse polarity
Temperature sensor must be installed on the master in a multi-controller system. Temperature
sensor inputs on slaves are disabled.
If sensor is open, short, reverse polarity or missing system will operate as if sensor was at 25
°
C.
Sensor temperature can be read directly on the IPN-ProRemote. Sensor voltage when connected
reads 2.98V at 25
°
C, changing at +10mV/
°
C.
SPECIFICATIONS
SPECIFICATIONS
Solar Boost 1524iX
Output Current Rating
20 amp maximum (12V battery & 12V PV’s)
•
15 amp maximum (battery or PV’s > 12V nominal)
Nominal Battery Voltage
12 / 24VDC
PV Input Voltage
57VDC maximum (Recommend maximum V
OC
at STC
≤
45.6VDC)
Power Consumption
0.20W typical standby
•
plus 0.40W each for charge ON & Load ON
Charge Algorithm
3-stage Bulk/Acceptance/Float
•
plus automatic Equalize
Acceptance Voltage
14.2VDC
ℵ
fixed (range 10.0 – 40.0VDC
ℑ
)
Float Voltage
13.2VDC
ℵ
fixed (range 10.0 – 40.0VDC
ℑ
)
Equalization Voltage
15.2VDC
ℵ
fixed (range 10.0 – 40.0VDC
ℑ
)
Voltage Setpoint Limit
15.5VDC
ℵ
fixed (range 10.0 – 40.0VDC
ℑ
)
Single output configurable as either: 20 amp 12V / 15 amp 24V load controller –or– 2A auxiliary battery charger
2A typical, same charge voltage as primary battery
20 amp / 15 amp maximum, ON
≥
12.6VDC
ℵ
/ OFF
≤
11.5VDC
ℵ
(Range 10.0 – 40.0VDC
ℑ
, or battery amp-hours from full
ℑ
)
Auxiliary Output
•
Aux. Battery Charge
•
Load Control
•
Dusk-to-Dawn Control
ℑ
Variable Post–Dusk and Pre–Dawn timers
ℑ
, Range 0.5 – 20.0 hours
Temperature Compensation
Optional sensor adjusts charge voltage based on battery temperature
–5.00 mV/
°
C/cell correction factor (Range 0.00 to –8.00 mV/
°
C/cell
ℑ
)
•
sensor range –60 to +80
°
C
Power Conversion Efficiency
97% typical @ 28V / 12A Output
Physical Configuration
and Dimensions
Open frame construction with conformal coated electronics mounted to rear of 5.3” x 5.3” (13.5cm x 13.5cm)
clear anodized aluminum face plate. Mounts into standard 4
11
/
16
” (11.9cm) square electrical box which is included.
Volt/Amp Accuracy/Range
Battery voltmeters 40.0VDC
±
0.50% FS
•
PV voltmeter 60.0VDC
±
0.50% FS
Ammeters 25.0A
±
0.50% FS
Communication
Blue Sky Energy’s proprietary IPN Network interface
Environmental
–40 to +50
°
C, 10 – 90% RH non-condensing
As a part of our continuous improvement process
ℵ
Voltages double for 24V battery
specifications
are
subject
to
change
without
prior
notice
ℑ
With IPN-ProRemote
FIVE YEAR LIMITED WARRANTY
Blue Sky Energy, Inc. (hereinafter BSE), hereby warrants to the original consumer purchaser, that the product or any part thereof shall be free from defects due to
defective workmanship or materials for a period of five (5) years subject to the conditions set forth below.
1.
This limited warranty is extended to the original consumer purchaser of the product, and is not extended to any other party.
2.
The limited warranty period commences on the date the product is sold to the original consumer purchaser. A copy of the original purchase receipt identifying purchaser
and date of purchase, must accompany the product to obtain warranty repairs.
3.
This limited warranty does not apply to, and future warranty shall become void, for any product or part thereof damaged by; a) alteration, disassembly or application of a
foreign substance, b) repair or service not rendered by a BSE authorized repair facility, c) accident or abuse, d) corrosion, e) lightning or other act of God, f) operation or
installation contrary to instructions pertaining to the product, or g) cosmetic aging.
4.
If BSE’s examination of the product determines that the product is not defective the consumer shall be charged a test and evaluation fee of $20 and be responsible for all
transportation costs and insurance related to returning the product to the consumer. The consumer is ultimately responsible for proper installation and operation of the
product and BSE’s prior troubleshooting assistance shall not serve as a waiver of the test and evaluation fee. The test and evaluation fee is subject to change without
prior notice.
5.
If within the coverage of this limited warranty, BSE shall repair or replace the product at BSE’s sole discretion and return the product via standard ground transportation of
BSE’s choosing within the continental US. The consumer shall be responsible for all transportation costs and insurance to return the product outside the continental US,
and for all transportation costs and insurance related to expedited return of the product. BSE’s liability for any defective product or any part thereof shall be limited to the
repair or replacement of the product. BSE shall not be liable for any loss or damage to person or property, or any other damages, whether incidental, consequential or
otherwise, caused by any defect in the product or any part thereof.
6.
Any implied warranty for merchantability or fitness for a particular purpose is limited in duration to the length of this warranty.
7.
To obtain warranty repairs, contact BSE at 760-597-1642 to obtain a Returned Goods Authorization (RGA) number. Mark the outside of the package with the RGA
number and return the product, postage prepaid and insured to the address below. The consumer is responsible for all transportation costs and insurance related to
returning the product to BSE, and for any shipping damage which may void the warranty or increase the cost of repairs.
Blue Sky Energy, Inc.
2598 Fortune Way, Suite K
Vista, CA 92081 USA
800-493-7877
•
760-597-1642
•
Fax 760-597-1731
•
www.blueskyenergyinc.com