8
Blue Sky Sub 12D
Owners Manual, V1.0
Switch Settings
Max Analog Input & Output Level
-
Default factory setting is +12 dBu for both.
-
+12 dBu / +24 dBu options
-
In the analog mode, with the input switch set to +24 dBu , +4 dBu in analog equals -20 dBFS
in digital.
-
In the analog mode with the input switch set to +12 dBu, -8 dBu in equals -20 dBFS in digital.
-
With the max Analog input level set to +24 dBu, and the analog output level set for +12 dBu,
the analog gain is one (1).
-
If the max input level is set for +24 dBu, any output level set to +24 dBu, the analog gain is
one (1).
-
You can use a combination of input analog input level switches and output switches to
increase or decrease the analog output levels.
Mode of Operation
-
With the Sub 12D crossover mode on, the Sub 12D has an 80 Hz 12 dB per octave high
pass filter on the monitor outputs, including the digital left and right out, and a 24 dB per
octave low pass filter feeding the Sub 12D.
-
The cutoff frequency can be changed with software through the USB interface.
-
With the sub direct mode switch on, the crossovers are disabled; the left right outputs and
digital left right output are muted. This mode may be used when the Sub 12D is used with a
Blue Sky BMC or the Blue Sky AMC controller.