background image

Ion

 

Press

 

this

 

button

 

to

 

anion air purifying function,indicator light green.

Full water indicator light

When water tank is full,indicator light shows red.Please empty the water tank 

and back water tank back in correct place.

Humudity and timi ng indicator light

The

 

indicator

 

light

 

has

 

following

 

function

.

1.

When

 

power cord is connected, it shows 

- - ,

enter

 

into

 

standby mode

.

2.When press the power button,shows 

ambient humidity.

3.

When set a humidity, then shows the select humidity.

4.W

hen set a time to power on/off, will show set time period

5.

When press timmer button above 4 seconds,will show ambient temperature. 

6.

When

 

ambient

 

temperature

 < 5℃ ,

will

 

show 

"CL"

.

7.

When

 

ambient

 

temperature

 > 38℃,

will

 

show 

"CH"

.

8.

When

 

ambient

 

humidity

 < 20%RH 

,will

 

show

 "LO"

.

9.

When

 

ambient

 

humidity

 > 92%RH ,

will

 

show 

"HI"

.

10.

When temperature and humidity sensor failure, it will show

 "E1".

O p e r a t i ng I nstructions

Once plu g in,ha ve buz zer beeping ,initia l st at e is 5 0% RH ,lo w wind spe ed.

Pres s th e power butto n to start work ,e nter n ormal d eh umidifi cation mode,

can adju st humi di ty and wind spe ed if need ed.

1.

Po w e r

 

on

2 .

Power

 

off

Press

 

power

 

button

 

to

 

stop

 

working,can not unplug power cord directly.

Water

 

tank

 

drainage

Water tank capacity is 8.2L,when reach full water level,full water indicator 

light turn to green.Then the unit automatic stop work,buzzer buzzes 15 times to

warning users,that water in the tank must be emptied.

Water

 

tank emptied

1. 
2. 

Empty

 

the water in tank.

2

.

Clean water tank with cold water or warm water, do not use detergent, steel 

wool, dust cloth, gasoline, benzene, diluent or other solvents to clean tank.

May damage the water tank and cause a leakage.

3 .

W h e n i n s t a l l w a t e r t a n k , p r e s s i t t i g h t l y . I f t a n k i s n o t p l a c e d p r o p e r l y ,

 f u l l w a t e r s e n s o r w i l l a l a r m , t h e u n i t w i l l n o t w o r k .

Continuous water drain

The unit have a 

11~12mm)

to 

outlet water as following.

1. 

Remove the rubber blocklet. 

 2.Insert plastic pipe into the drainage.

3. 

Take out water tank,put rubber blocklet into water tank drain as image

③,

then

 

install

 

the

 

water

 

tank

.

continuous water drainage,use a plastic pipe(dia.

1

2

3

Automatic

 

water drain

The unit have 
Use

 

a

 

water

 

pipe

 

length

 

less

 

than

 

6m,dia.6mm,insert into the auto 

water drainage.(drainage

 

divide can't exceed 6 meters. drainage 

height should lower than the machine),the steps as following.

1. 

Remove the rubber blocklet in auto water drainage.

2. Insert water pipe into the drainage.

3. 

Take out water tank,put rubber blocklet into water tank drain as image

③,

then

 

install

 

the

 

water

 

tank

.

4. Press the auto water drain button.

automatic

 

water drain function.

1

2

3

3.

Non-volatile memory

The system has automatic memory function,when it suddenly power off during 

operation,will start work auto when power on,do not need to press power button.

Ion

Full water

Press the water tank on both sides,then pull the water tank out.

Notes

1.Do not remove the float in the water tank,make water full sensor will not 

work,cause the machine unable to work properly .

Summary of Contents for OL70-585E

Page 1: ...OL70 585E Executive Standard GB T 19411 2003 Blue Water Group Pty Ltd Tel 27 0 74 318 1808 Email sales bluewater biz Web www bluewater biz User s Manual Blue Water Group Pty Ltd ...

Page 2: ...isture reduces the level of humidity in the air Lightweight portable design low temperature operation automatic defrosting 5 C Room Temp 12 C defrost per 30 minutes 12 C Room Temp 20 C defrost per 45 minutes Selectable humidity Could set different humidity level according to your requirement Anion design Electrostatic dust removal clean air sterilization function OL70 585E Important Please read al...

Page 3: ...our fingers or other items into air inlet or outlet 8 Do not sit on this machine 9 Drain the tank as required before move the unit 10 Install drain pip properly then water can be drain continuously 11 Please contact us or your local services if power plug damaged 12 Do not use the unit at place that long time no unsupervised 13 Unplug power cord when the machine is not used 1 Keep the appliance in...

Page 4: ...Automatic dehumidification Press this button to enter auto mode could adjust humidity manually auto adjust wind speed Indicator light is green when enter into auto dehumidification mode dehumidification Up button Press this button to adjust humidity and set time Humidity adjustment sequence is 50 55 60 65 70 75 80 85 90 95 Down button Press this button to adjust humidity and set time Humidity adju...

Page 5: ...k must be emptied Water tank emptied 1 2 Empty the water in tank 2 Clean water tank with cold water or warm water do not use detergent steel wool dust cloth gasoline benzene diluent or other solvents to clean tank May damage the water tank and cause a leakage 3 When install water tank press it tightly If tank is not placed properly full water sensor will alarm the unit will not work Continuous wat...

Page 6: ...panel clean automatic water drain outlet Remove shell connect water pump properly Remove shell replace pump Please contact us if need any support Please do not diisassembling machine repair athout authorization When the machine runs or stops it hears the sound of refrigeration circulation which is normal not failure It is normal for air outlet to exhaust hot air If water tank drainage do not have ...