minutes to detect the spa temperature and then to heat to 
the  set  temperature  if  needed,  depending  upon  mode. 
When  the  low  speed  turns  on  automatically,  it  cannot  be 
deactivated from the panel; however, the high speed may be 
started.

 

Blower

  (optional) 

This button is used to turn the blower on and off. If left on, 
the blower automatically turns off after 15 minutes. 

Jets 2

 (optional) 

If your system has a pump 2 installed instead of a blower, it 
behaves exactly like a blower would. 

Preset Filter Cycles 

The  first  filter  cycle  begins  6  minutes  after  the  spa  is 
energized.  The  second  filter  cycle  begins  12  hours  later. 
Filter duration is  programmable  for  2,  4,  6,  8  hours  or  for 
continuous filtration (indicated  by  “ 

”).  The  default 

filter time is 2 hours. To program, press “Temp” or “Set,” then 
“Jets.”  Press “Temp” or “Set” to adjust.  Press “Jets” to exit 
programming. 
The blower purges for 30 seconds at the beginning of each 
filter cycle.  The low speed of the pump runs during filtration 
and  the  ozone  generator  (if  installed)  will  be  enabled.

Light

 

Press the “Light” button to turn the light on and off. If left on, 
the light automatically turns off after 4 hours. 

Mode 

Mode is changed by pressing the “Temp” or “Set” button, then 
pressing the “Light” button. 

Standard  Mode

  is  programmed  to  maintain  the 

desired  temperature.  Note  that  the  last  measured  spa 
temperature  displayed  is  current  only  when  the  pump  has 
been running for at least 2  minutes. “  

 ” 

will 

be 

displayed momentarily when you switch into Standard Mode. 

Economy Mode

 heats the spa to the set temperature 

only during filter  cycles.   “ 

”  will  display  solid  when 

temperature  is  not  current,  and  will  alternate  with 
temperature when temperature is current. 

Sleep  Mode

  heats  the  spa  to  within  20°F/10°C  of  the 

set temperature only during filter cycles. “   ”will display solid 
when  temperature  is  not  current,  and  will  alternate  with 
temperature when temperature is current. 

Freeze Protection 

If  the  temperature  sensors  detect  a  drop  to  below 
44°F/6.7°C  within  the  heater,  the  pump  and  blower  will 
automatically  activate  to  provide  freeze  protection.  The 
equipment stays on until 4 minutes after the sensors detect 
that the spa temperature has risen to 45°F/7.2°C or higher. 
In colder climates, an optional additional freeze sensor may 
be added to protect against freeze conditions that may not be 
sensed  by  the  standard  sensors.  Aux  freeze  sensor 
protection  acts  similarly  except  with  the  temperature 
thresholds determined by the switch and without a 4-minute 
delay  in  turnoff.  See  your  dealer  for  details

.

 
 

 

 
 