No message on display. Power has been cut
off to the spa.
The control panel will be disabled until power
returns. Spa settings will be preserved until
next power up.
Temperature unknown.
After the pump has been running for 2
minutes, the temperature will be displayed.
“Overheat” - The spa has shut down. One
of the sensors has detected 118°F/48°C at
the heater.
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. Once the
heater has cooled, reset by pushing any
button. If spa does not reset, shut off the
power to the spa and call your dealer or
service organization.
“Overheat” - The spa has shut down. One of
the sensors has detected 110°F/43°C at the
heater.
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. Once the
heater has cooled, reset by pushing any
button. If spa does not reset, shut off the
power to the spa and call your dealer or
service organization.
“Ice” - Potential freeze condition detected.
No activation required. The pump and blower
will automatically activate regardless of spa
status.
Spa is shut down. The sensor that is
plugged into the Sensor “A” jack is not
working.
If the problem persists, contact your dealer or
service organization. (May appear temporarily
in an overheat situation and disappear when
the heater cools.)
Spa is shut down. The sensor that is
plugged into the Sensor “B” jack is not
working.
If the problem persists, contact your dealer or
service organization. (May appear temporarily
in an overheat situation and disappear when
the heater cools.)
Sensors are out of balance. If alternating with
spa temperature, it may just be a temporary
condition. If flashing by itself, spa is shut down.
If the problem persists, contact your
dealer or service organization.
A
significant
difference
between
temperature sensors has been detected.
This could indicate a flow problem.
Check water level in spa. Refill if necessary. If the
water level is okay, make sure the pumps have been
primed. If problem persists, contact your dealer or
service organization.
Persistent low flow problems. (Displays on
the fifth occurrence of “ “ message within
24 hours.) Heater is shut down, but other
spa functions continue to run normally.
Follow action required for “
“ message.
Heating capability of the spa will not reset
automatically; you may press any button to
reset.
Possible inadequate water, poor flow, or air
bubbles detected in the heater. Spa is shut
down for 15 minutes.
Check water level in spa. Refill if necessary. If water
level is okay, make sure the pumps have been
primed. Press any button to reset, or this message
will automatically reset within 15 minutes. If problem
persists, contact your dealer or service organization.
Inadequate water detected in heater.
(Displays on third occurrence of “
“
message.) Spa is shut down.
Follow action required for “ “ message. Spa
will not automatically reset. Press any button
to reset.
!
!
!
Diagnostic Messages
Message
Meaning
Action Required