Troubleshooting

Problem Possible 

Cause 

Action 

Compressor
will not start

Power connection failure

Check Power Cord and plug it in

Power switch is in off position

Change it on position

Temperature set point is too high

Correct temperature set point

The door is opened too frequently

-

Loading of too much warm or
moist product

-

The unit does not
refrigerate well

moist product

Not enough ventilation

Move the unit in a well
ventilated place with at least 7
inches of clearance on all sides

Condenser is clogged

Clean it

Condensation
on cabinet exterior

High moisture air can produce
dews during the rainy season

Wipe with cloth

The following is not an indication of problem or malfunction; 

A water-flowing sound can be heard when the unit is operating.

Thi i th

d f

f i

t fl

i

This is the sound of refrigerant flowing.

6

Summary of Contents for BACB53

Page 1: ...CB83 BACB86 BACB96 BACB71M BACB74M BACB83M BACB86M BACB96M Blue Air reserves the right to make product modification at any time Specifications and Designs are subject to change without notice IMPORTANT SAFETY INSTRUCTION SAVE THESE INSTRUCTIONS Visit our website at www blueairinc com Installation Operation Manual Chef Base ...

Page 2: ...Castors 6 7 Service Contact Blue Air Refrigeration has a Nationwide Service Network to provide timely services to our customer s needs Please call or fax us at the following numbers Blue Air Refrigeration Nationwide Service Network Toll Free 1 866 677 8500 TEL 310 808 0102 Fax 310 808 0242 0262 Fax 310 808 0242 0262 2 ...

Page 3: ...Type of refrigeration system Indirect cooling Fan blowing Control Thermostat Control Drawers 2 4 4 4 4 4 Rated Voltage AC115V 60Hz Type of Power Cord NEMA 5 15 Amps 2 5 3 2 3 2 3 9 3 9 3 9 Compressor HP 1 5 HP 1 5 HP 1 5 HP 3 8 HP 3 8 HP 3 8 HP Refrigerant R 134a g Range of Temperature 32 40 F Models that has M on last digit of the Model Name have V shape of Top Specifications and Designs are subj...

Page 4: ...unded wall receptacle to prevent electrical shock and fire hazards 2 Do not plug other electrical units into same wall receptacle this unit is plugged into 3 Do not use an extension cord Maintenance Cleaning 3 Do not use an extension cord 4 Compressor warranties are void if the compressor burns out due to low voltage Maintenance Cleaning 1 To maintain proper refrigeration performance the condenser...

Page 5: ...binet interior 2 The controller has been preset NORMAL position at the factory 3 Set the control knob toward COOL for higher temperature and COLD for lower temperature 4 The thermostat controls compressor s ON OFF by sensing inside temperatures of cabinet 5 The unit is equipped with an off cycle defrost 5 ...

Page 6: ... or moist product The unit does not refrigerate well moist product Not enough ventilation Move the unit in a well ventilated place with at least 7 inches of clearance on all sides Condenser is clogged Clean it Condensation on cabinet exterior High moisture air can produce dews during the rainy season Wipe with cloth The following is not an indication of problem or malfunction A water flowing sound...

Page 7: ...Installing Casters 1 Remove the outer packing 2 Install the castors in the area 3 Maker sure that castors with brakes should be installed in front 7 ...

Page 8: ...o BLUE AIR within twelve 12 days from the date of installation The term Original Purchaser as used herein shall be deemed to refer to that person firm association or company for whom the refrigeration unit refers to herein is originally installed Extended Warranty One 1 year extended warranty for parts labor is available for purchase at the time of purchasing equipment from our dealers Five Year C...

Page 9: ...ponsible for any warranty claims made on products sold or used outside the United States Improper Electrical Connections BLUE AIR is not responsible for the repair or replacement of failed or damaged components resulting from electrical power failure the use of extension cords low voltage or voltage interference to the unit No Implied Warranty of Merchantability or Fitness for a Particular Purpose...

Page 10: ...MEMO 10 ...

Page 11: ... extended Warranty available If you are interested please contact Blue Air Customer Service Dept Yes I would like the extended warranty No I would not like the extended warranty Cut along dotted line and mail it back to BLUE AIR Customer Service Dept 223 W Rosecrans Ave Gardena CA 90248 y y Signature of Business Owner Date The Warranty becomes void if the attached warranty card is not filled out a...

Page 12: ...223 W Rosecrans Ave Gardena CA 90248 Toll Free 1 866 677 8500 BLUE AIR TEL 310 808 0102 Fax 310 808 0242 0262 Visit our website at www blueairinc com ...

Reviews: