3.1.2
Sensor operation check
1)
Bin switch sensor
-
Can be checked while the machine is in operation. (Water supply, Freezing, or Harvesting Cycles.)
-
Press and hold down the plate flap on bin switch.
-
[ FUll ] will be displayed after 10 seconds if the bin switch properly works.
-
[ FUll ] will disappear within 5 seconds after releasing the plate flap.
2)
Water level sensor
-
Can be checked while the machine is in operation. (Water supply, Freezing, or Harvesting Cycle.)
-
Lift the float switch to its highest level, and then proceed to slowly push the float switch all the way
down to the lowest position.
-
The display will show a green light to indicate the float is at the lowest position. A Red light will
appear if the float switch cannot sense the lowest position.
Flap
Float