content
Ambient
Temp
(
º
F/
º
C)
Water temp(
º
F/
º
C)
50
º
F/10
º
C
70
º
F/21
º
C
90
º
F/32
º
C
High pressure in
freezing
(psig / kgf/
㎠
g)
after
5min
70/21
277.4
19.5
295.8
20.8
305.8
21.5
80/27
336.4
23.7
339.9
23.9
343.5
24.2
90/32
371.2
26.1
379.1
26.7
384.0
27.0
100/38
416.7
29.3
420.3
29.6
428.1
30.1
Stable
70/21
287.3
20.2
288.0
20.3
290.2
20.4
80/27
312.9
22.0
323.6
22.8
325.0
22.9
90/32
367.7
25.9
371.2
26.1
371.9
26.2
100/38
399.0
28.1
411.1
28.9
412.5
29.0
Low pressure in
freezing
(psig / kgf/
㎠
g)
after
5min
70/21
73.3
5.2
91.7
6.5
95.3
6.7
80/27
87.5
6.2
96.7
6.8
101.0
7.1
90/32
98.9
7.0
103.8
7.3
108.8
7.7
100/38
106.7
7.5
112.4
7.9
117.3
8.3
Stable
70/21
56.9
4.0
60.4
4.3
61.2
4.3
80/27
62.6
4.4
63.3
4.5
65.4
4.6
90/32
65.4
4.6
65.4
4.6
68.3
4.8
100/38
67.6
4.8
68.3
4.8
69.0
4.9
High pressure in
harvest
(psig / kgf/
㎠
g)
Stable
70/21
148.6
10.5
177.8
12.5
189.2
13.3
80/27
158.6
11.2
182.1
12.8
192.0
13.5
90/32
171.4
12.1
190.6
13.4
202.0
14.2
100/38
182.8
12.9
199.1
14.0
219.8
15.5
Low pressure in
harvest
(psig / kgf/
㎠
g)
Stable
70/21
124.5
8.8
152.2
10.7
162.1
11.4
80/27
133.0
9.4
153.6
10.8
165.0
11.6
90/32
143.7
10.1
160.7
11.3
170.7
12.0
100/38
153.6
10.8
167.8
11.8
185.6
13.1
Summary of Contents for BLMI-300A
Page 1: ...SERVICE MANUAL BLMI 300A BLMI 500A BLMI 650A BLMI 900A Ver200626 ...
Page 35: ...4 Circuit diagrams and technical data 4 1 Circuit diagrams 4 1 1 BLMI 300A 115V 60Hz ...
Page 36: ...4 1 2 BLMI 500A 115V 60Hz ...
Page 37: ...4 1 3 BLMI 650A 208 230V 60Hz ...
Page 38: ...4 1 4 BLMI 900A 208 230V 60Hz ...