2.3.2.2
Parameter code meaning
Number Display
Features
Range
Adjustable value
1
P-1
Set evaporator temperature for
harvest control
5 ~ 30
℃
41 ~ 86
℉
1
℃
, 1
℉
2
P-2
HI
Set harvest delay time when
ambient temperature is high.
60 ~ 300
sec
5 sec
LO
Set harvest delay time when
ambient temperature is low.
60 ~ 300
sec
5 sec
3
P-3
drainage cycle interval
1 ~ 10
1,2,5,10
4
P-4
Sensor temperature correction
-2 ~ 2
℃
-4 ~ 4
℉
0.1
℃
1
℉
5
P-5
Set water pump delay time to
prevent ice from becoming slush.
10~60 sec
1
6
P-6
Set PCB program
25A~90A
7
P-7
Reset freezing cycle count
0~1
1
8
P-8
Set drainage time
10~20 sec
10
9
P-9
Set water supply time during
harvest
0~300 sec
10
10
P-10
Set bin switch error alarm
Y,N
Y,N