System Description Party Line Telephone System PLTS 

 

 

BCPT1010.SD.E2.doc, Version 1.0 

BlueCom AG, 1.3.1999 

9

 

3.2  Typical Applications 

 

3.2.1  Party Line Telephone System 

 

 
The diagram above shows a typical PLTS configuration. A PABX can be connected via its 4W 
E&M  interface  to  the  PLTS  system  via  a  decoder.  This  decoder  can  be  inserted  in  the  rack 
R7AH. 
 
 

3.2.2  Data Party Line System 

 

 
The J3KA are used to distribute the MODEM signal from the front end computer to the various 
Remote Terminal Units (RTU) in the various substations. The same J3KA amplifiers are used 
to  collect  the  signals  from  the  RTUs  and  transmit  it  to  the  front  end  computer  in  a  system 
control center. 
 
 

3.3  J3KA Testpoints 

Interruptible testpoints (U-links) are provided on all inputs and outputs which permit "bridged" 
in-circuit  measurements.   The  U-links  can  be  removed  which  isolates  the  bridging  amplifier 
from the system and permits measurements on the wiring side or the bridging amplifier side. 

To measure on the wiring side the testpoints to the left should be used.  To measure on the 
amplifier side the testpoints to the right should be used. 

The testpoints are identified with a number and have the following functions: 

  Testpoint 1 and 3 

Input 1 

  Testpoint 4 and 6 

Input 2 

  Testpoint 7 and 9 

Input 3 

  Testpoint 10 and 12 

Input 4 

J3KA

J3KA

J3KA

DTMF

Decoder

PABX

SETEL

SETEL

SETEL

SETEL

SETEL

J3KA

J3KA

J3KA

MODEM

Front End
Computer

MODEM

RTU

MODEM

RTU

MODEM

RTU

RTU

MODEM

Summary of Contents for PLTS

Page 1: ...BCPT1010 SD E2 doc Rev 1 0 BlueCom Ltd PLTS System Description Party Line Telephone System...

Page 2: ...red or should any user wish to make a suggestion for improving this handbook he is invited to send the relevant details to BlueCom Ltd Giessenstrasse 15 8953 Dietikon SWITZERLAND Telephone 41 44 748 4...

Page 3: ...defect and identification of the individual to be contacted if additional information is needed BlueCom products must be returned properly packed with transportation charge prepaid Except for the lim...

Page 4: ...Light Emitting Diode 10 4 J3KA Programming 11 4 1 Supply Voltage Range 11 4 2 Gain Range 11 4 3 Factory Programming 11 5 J3KA Technical data 12 5 1 Supply 12 5 2 Inputs 12 5 3 Outputs 12 5 4 Amplifier...

Page 5: ...phically seperated stations and one or several local drops to subcriber telephone sets within a station The trunk path may consist of any combination of radio pilot cable microwave fibre or power line...

Page 6: ...ABB MES standard Each bridging amplifier has its connecting cable V9CT The circuitry is arranged on three printed circuit boards which are designated Na Nb and Nc Na is the main board It is fitted wi...

Page 7: ...and maintenance of a system the frontpanel of the bridging amplifier is equipped with the following Testpoints on inputs and outputs Potentiometers for level adjustments A light emitting diode LED for...

Page 8: ...am L M H 1 2 1 3 1 4 14 16 1 3 5 7 27 25 Output 1 Input 1 L M H 2 1 2 3 2 4 17 19 4 6 11 13 31 29 Output 2 Input 2 L M H 3 1 3 2 3 4 20 22 7 9 15 17 35 33 Output 3 Input 3 L M H 4 1 4 2 4 3 23 25 10 1...

Page 9: ...front end computer in a system control center 3 3 J3KA Testpoints Interruptible testpoints U links are provided on all inputs and outputs which permit bridged in circuit measurements The U links can b...

Page 10: ...to output 4 Group 2 controls signals from input 2 Potentiometer 1 to output 1 Potentiometer 2 to output 3 Potentiometer 3 to output 4 Group 3 controls signals from input 3 Potentiometer 1 to output 1...

Page 11: ...n Range In addition to the adjustment by the potentiometers described in 3 4 three coarse gain ranges are provided for each output The range selection can be made by means of jumpers located on the Nb...

Page 12: ...edance 600 balanced Return loss 300 3400 Hz 14 dB Maximum output level 48 V supply 16 dBm 24 V supply 10 dBm 5 4 Amplifier Gain Continuously adjustable by means of multiturn potentiometers Ranges low...

Page 13: ...1999 13 5 5 Ambient condition Operating range 0 55 C Transportation and storage 20 55 C Humidity non condensing max 90 5 6 Mechanical Type printed circuit board 3 5 ASA units high 3 divisions wide Cod...

Page 14: ...ging amplifiers J3KA Connect the SETEL phones to the V9CT cables Interconnect the unit with the communication system via the V9CT cable delivered with each bridging amplifier J3KA 7 3 Installation Con...

Reviews: