Testing:
Test the light before installation ensuring that you use the correct voltage and the light is illuminated
correctly.
After installation ensure again that the light is illuminated correctly before the boat goes back into
the water and the lens label is removed.
After you boat goes back into the water check internally for water ingress around where the light is
installed.
P24 Dual Colour Operation
1.
When first turned on the light will start up in Dual Blue/White mode, if you turn the light off
and on again quickly it will then go to Blue mode. If you turn the light off and on again quickly
it will then go to White mode. If you turn the light off and on again quickly it will go to Dual
Blue/White Strobe mode. If you turn the light off and on again quickly it will strobe on blue. if
you turn off and on again quickly it will strobe in white. If you turn off and on again quickly it
will strobe alternate blue and white.
2.
When the light is turned off for more than 5 secs it will return to standard mode.
3.
The light output will adjust itself dependent on the surrounding temperature conditions.
P24 Single colour Operation.
1.
When powered up for the first time or from reset, the light will appear in the standard on
mode. When turned off and on again quickly it will then go to strobe mode.
2.
Switch off the light and leave for over 5 seconds, when the light is switched back on the light
will reset back in the standard mode.
P24CC (Colour change) Operation.
3.
When powered up for the first time or from reset, the light will appear in white and scroll
through the colour range and keep scrolling until stopped by any of the steps below.
4.
To pick a particular colour turn the light off and then on again quickly and the chosen colour
will be selected (approx. 1 Sec power cycle, this may take a little practice as too fast or slow
will not detect).
5.
If you switch off and on again quickly for the second time the light will start to strobe.
6.
Switch off the light and leave for over 5 seconds, when the light is switched back on the light
will reset back in the white mode.
7.
When the light colours become out of sync simply repeat step 4 to re-set to initial colour
cycle mode, the more lights installed this process may need to be more frequently repeated.
The light has internal indicator LED’s for fault finding, these are as follows:
Over voltage will flash red.(check the voltage to the light)
Under voltage will show a constant red. (check the voltage to the light)
Over temperature will show amber.(allow the light to cool down and check if submerged)
The light output will adjust itself dependent on the surrounding temperature conditions.