background image

U

=

P

=

  Note! 

3. Battery and device disposal 

 
 

 

 

Empty or damaged batteries are to deliver to authorised collection points. 

 
 

 
After removal from service, the instrument has to be disposed of eco-friendly. 

 
 

4. Application area 

 
The Gas detector GSP-1 is a high quality instrument and determined only for the detection of leaks within gas pipelines, 
gas tanks, gas meters and facilities for liquefied and natural gas. 
 
 

 

5. Product description 

 

The gas detector GSP1 is suitable in an outstanding way for the use within the area of heating and gas installations. 

 

The GSP1 can be used to examine gas pipelines, gas meters, gas tanks and other gas conducting components. The 
GSP1 can be used for room monitoring and concentration measurements as well. 
The gas sensor responds to all kinds of explosive gases (e.g. methane, propane, butane, etc.). The device is cali-
brated on the basis of room temperature and a density of 60% r.h. of methane (CH4). 
In delivery status the GSP1 is set to optical signals. However, acoustic alerts can be activated at any time and how 
they are needed by the user. 
 
 

  

Please charge batteries before using the device for the first time! 

 

Summary of Contents for GSP1

Page 1: ...50394 Version 09 2006 Part No 22628 o Subject to technical changes User Manual for Gas Detector with graphical LED Indicator Read the instructions before using the instrument Consider security advice...

Page 2: ......

Page 3: ...Gas Detector GSP1 Function button Graphical LED Indicator Measuring unit with gas sensor Flex arm ON OFF button Button for setting alerts...

Page 4: ......

Page 5: ...fety instructions 1 3 Battery and device disposal 2 4 Application area 2 5 Product description 2 6 Technical data 3 7 Use 4 8 Setting of the acoustic alerts 5 9 Charging 6 10 Safety instructions 7 11...

Page 6: ......

Page 7: ...he device or sensors Protection of the measuring instrument Keep the instrument away from paint solvent and glue and store it in a dry place Safety measures in order to maintain product warranty The i...

Page 8: ...an outstanding way for the use within the area of heating and gas installations The GSP1 can be used to examine gas pipelines gas meters gas tanks and other gas conducting components The GSP1 can be u...

Page 9: ...20 50 ppm Methane Batteries NiMH Hours of use approx 24 hours Auto off 5 minutes Size device 72 x 130 x 26 mm Size flex arm 295 mm incl sensor Temperature humidity for storage 5 C 40 C 23 F to 104 F...

Page 10: ...aces where they are assumed to be The measured concentration can be read of the graphical LED Indicator If the display has reached its highest status there is a constant beep as acoustic alert During...

Page 11: ...f 2 000 ppm Methane can be altered within the active range of measuring This can be done as explained in the following Press the button with the loudspeaker symbol LS for about a second and press the...

Page 12: ...tes the current battery status by a blinking LED segment During recharging the green POWER LED is blinking whereas the red LowBatt LED is glowing permanently When the battery is recharged completely b...

Page 13: ...If the device is stored at a temperature below 0 C 32 F it should be switched on at least 10 minutes before starting to work with it The gas detector GSP1 is not explosion protected and may therefore...

Page 14: ...struction In this case there are optical LED elements are flashing and acoustic ALARM LED blinks warnings Measuring can be started again by the ON OFF button A defect sensor is indicated by all segmen...

Page 15: ...9 12 Notes...

Page 16: ......

Page 17: ......