background image

 

                           For further information about this warranty,  

 

                             contact Prizer-Painter Customer Service at 1-800-449-8691 

 

factory authorized service agent located within 100 miles roundtrip from the location of the Product.  Service 
will be provided during normal business hours.  The Owner will be responsible for any and all costs associated 
with additional mileage, non-standard service or overtime, and special equipment required to remove the 
Product so that service may be performed.  Prizer-Painter reserves the right to deny warranty coverage for 
excessive installation delays.

 

 
Limited Cosmetic Component Warranty:  

This Warranty covers the repair or replacement of all cosmetic 

component flaws for thirty (30) calendar days from the date of delivery of the Product to the owner’s home 
from a BlueStar

® 

authorized dealer.  Cosmetic components include top grates, ring grates, plate rail, kick panel, 

body sides, glass, control panel, door panel, back guards, oven seals), front sides of hoods, and hoods strapping.  
Cosmetic components flaws include visible chips, scratches, dents, provided, however, that cosmetic flaws 
caused by freight damage are excluded.   
 

Limited Warranty on Floor Models Not Used For Demonstration:

  Floor Models are covered by a one (1) 

year limited functional parts and related services warranty, with proof of date of installation.  There is no 
cosmetic warranty of any kind for floor models. 
 

Limited Warranty on Floor Models Used For Demonstration:

  Floor Models used for demonstration are 

covered by a ninety (90) day limited parts warranty only, with proof of date of installation.  There is no service 
or cosmetic warranty of any kind for floor models. 
 

Limited Warranty on Product Refurbished

 

Refurbished Products are covered by a six (6) months limited functional parts and labor warranty, with proof of 
installation, as well as an additional six (6) months limited parts warranty.  There is no cosmetic warranty of 
any kind on Refurbished Product. 
 

Registration

 

Registration is strongly recommended.  While not necessary to effectuate warranty coverage, it is the best way 
for Prizer-Painter to communicate with you about important events and also provides additional warranty 
coverage.  TO REGISTER, please fill out the “Performance Checklist and Warranty Form” located online at 
www.bluestarcooking.com/support/product-registration.  Or mail the form located in the back of the Product 
Use and Care Manual to:  Warranty Department, Prizer-Painter Stove Works, 318 June Avenue, Blandon, PA 
19510-9566. 
 

Obtaining Warranty Service

 

If a Warranty claim is not submitted as required, such claim will be invalid and will not be honored. 
 
To obtain Warranty service, where applicable, the Owner must call the Service Center (toll free:  1-800-449-
8691) or fill out the online form at www.bluestarcooking.com/service to report a warranty claim, and may be 
required to, at the time, provide (1) the model number of the Product, (2) the serial number of the Product, (3) 
proof of delivery, (4) a signed installation receipt, (5) a description of the claimed defect, and (6) proof of 
purchase of the Product, including the original retail receipt or invoice to establish the Warranty Period.  Prizer-
Painter must be given an opportunity to inspect any Product subject to a warranty claim.  All warranty related 
service repairs must be performed by a factory authorized service agent. 
 
This Limited Warranty gives you specific legal rights, and you may also have other rights that may vary from 
state to state or province to province. 
 

Out of Warranty Product

 

 

Summary of Contents for RBCT

Page 1: ...1 DROP IN COOKTOP MANUAL Drop in Cooktop RBCT ...

Page 2: ...toreorusegasolineorotherflammablevapors and liquids in the vicinity of this orany otherappliance WHATTO DO IF YOU SMELLGAS Do not try to light any appliance Do not touch oractivateany electricalswitch Do not useany phonein yourbuilding Immediately call yourgas supplierfroma neighbor sphone Follow thegas supplier s instructions If you cannot reach yourgas supplier callthefire department Installatio...

Page 3: ... reference In the event you require parts or service this information will be needed to ensure you receive the highest quality service we can provide DATE OF PURCHASE DEALER S NAME DEALER S ADDRESS DATE OF INSTALLATION INSTALLER S NAME INSTALLER S ADDRESS MODEL NUMBER SERIAL NUMBER ...

Page 4: ...tant safety precautions 1 Before any maintenance or repairs are per formed disconnect the appliance from the electric supply 2 Your appliance should be installed by a qualified gas installation technician Have the technician show you the exact location of the gas shutoff valve on the incoming gas line so you know how to turn off the gas if necessary 3 In the event of a power failure do not at temp...

Page 5: ...ur exhaust hood be powerful enough to move a minimum of 300 cfm Dimensions A and B must be a minimum of 6 150mm from side walls or cabinets Dimension D must be at least 1 1 2 38mm from back wall to the cooktop If installed in a countertop along a wall at the rear the surface must be inflammable material extending at least six inches upward When making the cut out be sure to follow the dimensions t...

Page 6: ...sibility 6 Remove and unpack any accessories shipped with your appliance Make sure no hardware or accessories are left to be disposed of unintentionally POSITIONING 1 The importance of the proper installation of gas cooking equipment cannot be over stressed Proper performance of the equipment is dependent in great part on the compliance of the installation with the manufacturer s specifications 2 ...

Page 7: ...ea sons Under no circumstances should the factory installed regulator be removed or by passed 8 The factory installed pressure regulator will withstand an input pressure of PSI 12 wc If the incoming pressure ex ceeds the maximum rating a step down regulator is required 9 The appliance and it individual shut off valve must be disconnected from the gas supply line during any pressure testing in exce...

Page 8: ...appliance is equipped with a three pronged grounding plug for your protec tion against shock hazard and should be plugged directly into a properly grounded receptacle Do NOT cut or remove the grounding prong from this plug If the appliance is not grounded or its po larity is reversed severe shock hazards can exist If present the optional rotisserie motor must be also be grounded in accordance with...

Page 9: ...po sure to moisture may cause these cast parts to rust To light a burner turn the corresponding control knob to HIGH This knob is a gas control valve and an electric switch Turning to the High posi tion begins the ignition sequence The igniters begin to click As gas flows through the piping to the burner the sparking ignites it After the flame lights the igniter senses its heat and the clicking au...

Page 10: ...spatula or sim ilar or any metal tool to scrape these sur faces Do NOT permit citrus or tomato juices to sit and dry on these surfaces Wipe such spills immediately Citric acid will dis color stainless steel BURNERS The ring grates and top grates of your ap pliance may be effectively cleaned with ho soapy water In the event of heavy soiling a commer cially available oven cleaner may be safe ly used...

Page 11: ...r different result Insure electrode is plugged in Insure electrode is properly lined up Insure electrode is not cracked spark not in correct place Burner lights clicking won t stop Insure electrode wires are properly connected after cleaning Call for service LAZEY flame floating larger in size than normal Air shutter adjustment LIFTING flame well defined with visible inner core noisy gap between b...

Page 12: ... head screwdriver picture 4 6 Install the new igniter securely to the burner head in proper alignment picture 5 7 Reinstall the burner assembly a Lean over and look inside to locate the round brass orifice which is where the gas enters b Be sure when reinstalling venturi burner tube connected to burner head that the end fits over the brass orifice picture 6 c Make sure burner head sits level with ...

Page 13: ..._________________________ e mail _______________________________________ Installer s Name ___________________________ Telephone ____________________________________ Company _________________________________ Dealer _______________________________________ Telephone ________________________________ CHECK ALL THAT APPLY Appearance and Aesthetics Electrical Connection Exterior Correct voltage Top secti...

Page 14: ...s and nursing homes This Warranty does not cover Products installed outside the U S or Canada This Warranty does not apply to gas type conversions on cooking appliances not completed by a certified gas technician licensed plumber or certified BlueStar servicers Full Two Year Warranty Product Registration is not required to obtain Warranty Coverage but is highly recommended for optimal servicing an...

Page 15: ...ed Warranty on Product Refurbished Refurbished Products are covered by a six 6 months limited functional parts and labor warranty with proof of installation as well as an additional six 6 months limited parts warranty There is no cosmetic warranty of any kind on Refurbished Product Registration Registration is strongly recommended While not necessary to effectuate warranty coverage it is the best ...

Page 16: ...replacement of a part or Product under this Warranty does not extend the Warranty period If the Product is removed from the property where it was originally installed Slight color variations may be noticed because of differences in painted parts kitchen lighting product placement and other factors this warranty does not apply to color variations Service calls to educate the customer on proper use ...

Page 17: ...ESULTING FROM BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so these provisions may not apply to you Where Can Any Legal Remedies Be Pursued Please see the Arbitration Clause and Related Provisions which affect your legal rights Read this Arbitration Clause and its related provisions careful...

Page 18: ...rising out of contract and tort pursuant to statute or otherwise 3 CLASS ARBITRATION WAIVER ARBITRATION IS HANDLED ON AN INDIVIDUAL BASIS IF A DISPUTE IS ARBITRATED YOU AND WE EXPRESSLY WAIVE ANY RIGHT TO PARTICIPATE AS A CLASS REPRESENTATIVE OR CLASS MEMBER ON ANY CLASS CLAIM YOU MAY HAVE AGAINST US AND US AGAINST US OR AS A PRIVATE ATTORNEY GENERAL OR IN ANY OTHER REPRESENTATIVE CAPACITY YOU AND...

Page 19: ...w Prizer Painter will pay your share of the fees charged by the arbitration organization and arbitrator s beyond the first 200 Where permissible by law you may be required to reimburse Prizer Painter for the fees of the arbitration organization and arbitrator s in whole or in part by decision of the arbitrator s at the discretion of the arbitrator s 11 Survival and Enforceability of this Arbitrati...

Reviews: