- 19 -
CONTROL PANEL REMOVAL
The following procedure must be performed to properly remove the control panel.
1. Shut off power to the unit.
2. Remove the control panel, by first removing all the control knobs from the valve or thermostat stems. Continue to
remove the securing screws located in the upper flange located underneath the plate rail and the screws located
on the lower flange located above the pull out grease pan handles.
3. Disconnect the wires from the switch light and fan, carefully marking the location of the wires in order to rewire
the switches positioned in the new control panel, or to simply replace wires in the correct location.
4. With two fingers, put pressure on the tabs located on the back of the switch to enable it to be pressed forward and
out of the control panel. If replacing the control panel, remove all bezels to be reused.
5. Re-install switches into the control panel along with the bezels.
6. Rewire switches as per disconnected configuration.
7. Re-install control panel by reversing step 2.
8. Reconnect power to unit.
9. Re-test for proper operation.