Hardware User Manual - Argos3D-P33X
Last change: 22 June 2017
Version 6
© BECOM BLUETECHNIX 2017
Page 14 | 26
a.
Power Connector
b.
Ethernet
c.
General purpose input 1 & 2
d.
General purpose output 1 & 2
e.
Modulation Light Interface (not supported, please do not use)
f.
Trigger
g.
RS232 / RS485 (functionality depends on firmware version)
h.
DIP-Switch
i.
Reset-Button
j.
Debug-UART
k.
Status LED
4.3.1
Power Connector (a)
This 3.5mm terminal connector allows plugging a cable entry plug like
691361100002
from Würth Elektronik.
Compatible connectors from other manufacturers may be found as well.
No.
Signal
Type
Description
1
VIN
P
Positive power supply
2
GND
P
Power ground
Table 4-1: Power connector description
The pins of the power connector are protected against wrong polarity.
Voltage range: 18V to 30V.
Note
Use inherently limited power sources only!
4.3.2
Ethernet and PoE (b)
This is a standard straight RJ45 10/100/1000 Base-T compatible Ethernet connector.
The Argos3D-P330 and Argos3D-P331 supports PoE++ as alternative power source. Please use a valid
PoE++ (90W) injector or switch only. Using another PoE standard may cause the camera to be not fully
operational. Please check the status of your PoE connection in the StatusRegister. Pease refer to the
Software User Manual for additional information and a register description.
4.3.3
General purpose input 1 & 2 (c)
This 4 pole 3.5mm terminal connector allows plugging a cable entry plug like
691361100004
from Würth
Elektronik.