19
Just Power On
Power of
Output
100V
2000W
JP
110V
2200W
120V
2200W
US
220-240V
2200W
UK,EU
Over-load
100V
2000W<load<2500W,2min;
2500W<load,8~10S
Error Range:± 30W ;
Clear the alarm history
and reboot the unit.
110V
2200W<load<2750W,2min;
2750W<load,8~10S
120V
220-240V
Surge
4800W
100ms
Frequency
50/60Hz ± 0.5Hz
Default @60Hz
Frequency can be
tweaked to 50 or 60Hz.
Inverter
Efficiency
90%
/
Short-circuit
Protection
Yes
/
Over-temperature
Protection
80℃± 2
Recover Temp: 75℃± 2(for
hardware)
AC & DC will be turned off when SOC reaches 0%
DC Output
Cigarette
Lighter
Port *1
Voltage
12V
Share 10A current with 2*
DC5521 ports.
Current
10A
Over-load
Power
145W
2s, Turn off output function.
Short-
circuit
Protection
Yes
Turn off all DC output ports.
DC5521
*2
Voltage
12V
Share 10A current with
cigarette lighter port.
Current
10A
Over-load
Power
145W
2s, Turn off output function.
Short-
circuit
Protection
Yes
Turn off all DC output ports.