Operation
12
[ O ]
Turbo Cool Operation
Start Turbo Cool operation by pushing and holding the
- Button till you hear 4 short beeps
followed by a long beeps followed again by 4 short beeps. This will open the bypass flap and
switch the device to its highest power setting for 3 hours. In this setting your living space can be
cooled down noticeably by fresh evening and night air after a hot day.
Turbo Cool operation is switched off automatically when outside air temperature is too hot.
Dehumidification Operation
Push and hold the
- Button for 15 seconds to activate this mode. This operation can be used
in case of an application where the usual dehumidification level provided by the Comfort mode
is not sufficient (for instance in a basement room). The freeAir100 will beep three times and
blue LEDs will flash. Dehumidification will work at humidity levels as low as 45 % relative
humidity. Dehumidification is optimally controlled through constant measuring of absolute
humidity both inside and outside effectively suppressing humidity import through outside air.