General
6
[ G ]
Technical Data
Dimensions inside front
28 x 58 cm
Wall thickness
32 to 53 cm incl. stuck
(under 40 cm => deeper hood; over 53 cm => extension)
Air stream
20 to 100 m
3
/h
Heat supply gradient
87 % (by PHI criteria and EN 13141-8)
Heat recovery
94 % (at 50 % relative humidity)
Heat exchanger type
Counter current flow; Aluminum
Line voltage
95 to 265 V AC
Line fuse
3 A quick (on motherboard)
Line frequency
45 to 65 Hz
Energy usage
Standby
→ 1 W; 20 m
3
/h
→ 4 W;
50 m
3
/h
→ 13 W; 100 m
3
/h
→ 40 W (max. tube F7)
Weight
10 kg
Noise level in room
20 m
3
/h
→ 17 dB (A) (distance of 1 m);
30 m
3
/h
→ 22 dB (A);
50 m
3
/h
→ 34 dB (A); 100 m
3
/h
→ 51 dB (A)
Noise dampening
Standby
→ 52 dB;
Operation
→ 46 dB (DIN EN 20140-10; D
n
,
e
,
w
)
Control
Intelligent 5-step Comfort Control
Air stream control
Automatic; 8 speeds; volume constant; balanced ventilation
CO
2
control
Automatic
Dehumidification
Automatic and special operation
Summer cooling
Automatic and with Turbo Cool
Anti freeze protection
Automatic bypass-control at about -5°C outside
Temperature range
-40 to +50°C outside and 0 to +40°C inside
Filter
– supply air
Fine particle filter M5 (pollen protection) or F7 (allergy)
Filter
– exhaust air
Fine particle filter M5 (EN 779)
Color
Front plate primer (ready to paint or arrange)
DIBt license
Z-51.3-287
Summary of Contents for freeAir 100
Page 1: ...www bluMartin de Operating Manual G General O Operation I Installation S Service ...
Page 20: ...Installation 18 I Drawings ...
Page 22: ...Installation 20 I ...
Page 23: ...Installation 21 I ...
Page 24: ...Installation 22 I ...
Page 25: ...Installation 23 I ...
Page 26: ...Installation 24 I ...