Service
[ S ] 36
Summer Cooling
(°C)
A special feature of your freeAir100 is the active summer cooling. In the warm season the
device automatically activates a bypass in order to (mostly at night) cool down rooms with fresh
outside air. The amount of air will be increased, if necessary.
Select your desired temperature for the supply air room.
Note
This feature is only available in devices with a serial number of 2000 or higher.
Temperature is set to 22°C in older devices.
Room Area
(m
2
)
Enter here the number of square meters to be ventilated. Please factor in all connected rooms.
This input is the basis for minimum ventilation calculations.
Notes
• If you find the intermittent operation bothersome adjust the room area
to less than 60 m
2
at Comfort Level 1
or to less than 35 m
2
at Comfort Level 3.
• Adjust the Room Area to 60 or 75 m
2
to guaranty a level of minimum ventilation of 20 m
3
/h
for humidity control according to DIN 1946-6.