background image

14

160479 - Rev. 02 - 03/2020

Connection to the mains 

water supply

Check that the mains pressure 
is between 1 bar and 3,5 bar. To 
enhance the quality of the sparkling 
water dispensed, an incoming 
flow rate in excess of 3,5 lt/min is 
recommended.

Connect incoming water tube (1) to 
the drinking-water main, ideally with a 
tap upstream of the unit. 

Connect the outlet joint (2) directly 
to the chosen dispensing tap for the 
installation or to an external water 
cooler.

Insulate the tubes connecting the 
Box and the tap for all of their length 
in order to maintain the water inside 
fresh.

Once the pipes are attached, turn on 
the tap. Ensure there are no leaks.

CAUTION!

To connect the water cooler to the mains 
water supply, you will need to use a new 
set of connectors (joints, gaskets and 
pipes). 
Do not use a set of connectors that has 
already been used elsewhere.
The water pressure entering the unit 
must be between a minimum of 1,0 bar 
(0,10 MPa) and a maximum of 3,5 bar 
(0,35 MPa). 
For a proper installation of the system, 
the use of an anti-flooding system such 
as the Water Block (cod. 750133 8mm / 
cod. 750144 3/8”) or a similar device is 
compulsory.

Electrical connection

The connections must comply with 
local regulations. 

The grounding of the unit is a legal 
requirement.

Connect the power supply cable to the 
to the electric socket.

In this moment, the pump for filling the 
carbonator with water is activated

Open the dispensing tap in order to 
release any air in the circuit and to 
allow the pump to fill the carbonator 
with water.

After around 1-2 minutes, the sparkling 
water pump stops.

Fig. 14.1

1

2

Summary of Contents for INSTAFIZZ

Page 1: ...1 6 0 4 7 9 1 7 0 5 EN INSTAFIZZ Before installing or using the product read the precautions and general recommendations inside Us e M a i n t e n a n c e M a n u a l...

Page 2: ......

Page 3: ...tions of overvoltage category III placed upstream of the plug Check that the voltage shown on the serial number plate corresponds to the voltage being supplied at the installation site The unit must n...

Page 4: ...ENVIRONMENT 6 CERTIFIED 7 ASSOCIATIONS 8 INTERNATIONAL AWARDS 8 DESCRIPTION OF THE UNIT 9 TECHNICAL FEATURES TECHNICAL DATA PLATE 11 INSTALLATION 13 INSTALLATION OF THE CO2 CYLINDER 15 HANDLING THE G...

Page 5: ...instructions in this manual and retain the manual for future reference This publication is based on information available when approved for printing Continuing design refinements could cause changes...

Page 6: ...rical and Electronic Equipment WEEE By ensuring that the product is scrapped correctly you are helping to prevent potential negative consequences for the environment and for health The symbol on the u...

Page 7: ...alian Ministerial Decrees 174 of 06 04 2004 and 25 of 07 02 2012 Electrical safety This water cooler is designed manufactured and marketed in compliance with the safety objectives of the Machinery Dir...

Page 8: ...TE EUROPEAN AQUA AWARDS 2018 DUBLIN BEST MARKETING CAMPAIGN EUROPEAN AQUA AWARDS 2017 KRAKOW BEST ENVIRONMENTAL PRACTICE GREEN INITIATIVE BEST PROMOTION OF HEALTH AND HYDRATION EUROPEAN AQUA AWARDS 20...

Page 9: ...or combination with an external chiller The main features of the unit are as follows 1 liter professional carbonator Compact design in robust skinplate sheet Easy and quick installation for use in any...

Page 10: ...10 160479 Rev 02 03 2020 Front view Drinking water inlet pipe joint 8mm 5 16 1 Sparkling water outlet pipe joint 8mm 5 16 3 CO2 inlet pipe joint 8mm 5 16 2 1 2 3...

Page 11: ...11 160479 Rev 02 03 2020 Technical Features Technical Data Plate 16 Year of manufacture 12 Month of manufacture 014212 Serial number mod INSTAFIZZ...

Page 12: ...ssional carbonator pump 200 Lt h Supply 230 V 50 Hz Power 370 W 1 6 A Inlet water and CO2 8 mm 5 16 Outlet H2 O 8 mm 5 16 Dimensions LxWxH mm 166 x 439 x 417 Packaging dimensions LxWxH mm 180 x 555 x...

Page 13: ...n connects it to the electric supply following the manufacturer s instructions and according to the local safety regulations The end user is not permitted to access the internal service parts of the u...

Page 14: ...ins water supply you will need to use a new set of connectors joints gaskets and pipes Do not use a set of connectors that has already been used elsewhere The water pressure entering the unit must be...

Page 15: ...good level of carbonation before opening the faucet on the CO2 cylinder pull the ring of the remote safety valve 2 until water comes out of it When the cylinder is open to increase or decrease the le...

Page 16: ...s with other cylinders or surfaces dropping the cylinders or subjecting them to mechanical stress All of the above may compromise their integrity and resistance The cylinders must not be lifted by the...

Page 17: ...T USE a jet of water to clean the unit or detergents with abrasives Light scratches can be removed with CREAMY CLEANER cod 190104 Sanitization Notes The unit should be sanitized at first installation...

Page 18: ...18 160479 Rev 02 03 2020 Service history Installation Technician Date Notes Signature Maintenance Technician Date Notes Signature...

Page 19: ...efects The warranty does not include normal wear and tear to the components or any damage caused to the components due to negligent or improper use or due to a non standard installation The warranty s...

Page 20: ...ura srl Via Gandolfi 6 40057 Cadriano Di Granarolo Dell Emilia BO Italy Headquarters Via Erideo Marinucci 2 4 62019 Recanati MC Italy Tel 39 071 9710080 Fax 39 071 9710084 info blupura com www blupura...