background image

Blupura srl

- Sede legale -

Via F.lli Brancondi, 56

60025 Loreto (AN) Italy

- Sede operativa -

Via Erideo Marinucci, 2/4

62019 Recanati (MC) Italy

Tel 071 9710080

Fax 071 9710084

info@blupura.com

www.blupura.com

Summary of Contents for WAVE HOT

Page 1: ...OT WAVE BOX HOT Use M a i n t e n a n c e M a n u a l Us e M a i n t e n a n c e M a n u a l Before Install or use the product read to the precautions and general recommendations inside 1 6 0 3 7 2 1 6 0 2 EN ...

Page 2: ......

Page 3: ...ons of overvoltage category III placed upstream of the plug Check that the voltage shown on the serial number plate corresponds to the voltage being supplied at the installation site The unit must not be cleaned with a water jet Do not position other electrical equipment in the immediate vicinity of the water cooler Turn off the main water inlet tap if the unit is not to be used for a long period ...

Page 4: ... CERTIFIED 7 ASSOCIATIONS 8 INTERNATIONAL AWARDS 8 DESCRIPTION OF THE UNIT 9 DESCRIPTION OF THE KEYPAD 15 TECHNICAL FEATURES 16 INSTALLATION 19 HANDLING THE GAS CYLINDERS 25 FILTRATION OPTIONAL MOD WAVE HOT 26 SANITIZATION NOTES 29 ORDINARY MAINTENANCE 30 SERVICE HISTORY 31 WARRANTY CONDITIONS 32 ...

Page 5: ...PURA product We have designed and manufactured this product with great care to ensure that it will dispense water of the highest quality In order to get the most out of your water cooler please read the instructions in this manual and retain the manual for future reference ...

Page 6: ...ct should not be treated as domestic waste but should be taken to a dedicated recycling centre for electrical and electronic equipment Immediately prior to scrapping cut off the power cable For more information on the treatment recovery and recycling of this product please contact the appropriate local office the waste disposal service or the reseller from which the product was purchased Informati...

Page 7: ...sterial Decrees 174 of 06 04 2004 and 25 of 07 02 2012 Electrical safety This water cooler is designed manufactured and marketed in compliance with the safety objectives of the Machinery Directive 2006 42 CE the protection requirements of the Electromagnetic Compatibility Directive 2014 30 EU The electrical safety of the product is ensured only when it is properly connected to an efficient legally...

Page 8: ...ARDS 2015 ROME 2014 BEST PROMOTION OF HEALTH AND HYDRATION EUROPEAN AQUA AWARDS 2014 BUDAPEST 2013 BEST PRODUCT INNOVATION EUROPEAN AQUA AWARDS 2013 BERLIN 2012 BEST ENVIRONMENTALLY FRIENDLY PRACTICE EUROPEAN AQUA AWARDS 2012 ISTANBUL 2011 BEST PRODUCT DESIGN INNOVATION EUROPEAN AQUA AWARDS 2011 ODESSA 2010 BEST ENVIRONMENTALLY FRIENDLY PRACTICE EUROPEAN AQUA AWARD 2010 PRAGUE ...

Page 9: ...I 304 for hot water 3 supply options cold water cold sparkling water hot water Self diagnosing system and alarm in case of lack of mains water lack of CO2 in cylinder and water leakage ENERGY SAVING control when needed puts the machine into stand by mode with an energy saving of 75 of full operational energy Body and internal parts made entirely from stainless steel WAVE received third prize for B...

Page 10: ...n Adjustable boiler thermostat Adjustable thermostat Drinking water inlet pipe joint 8mm Boiler condensation drain hose Ø8mm CO2 inlet pipe joint 8mm only mod FIZZ Ice bank overflow Sparkling water outlet pipe 8mm only mod FIZZ Room temperature water outlet pipe 8mm Sparkling water outlet pipe 8mm only mod FIZZ ...

Page 11: ...11 1 1 Power cable Rear view mod Wave Box Hot 60 ...

Page 12: ...12 External Front View 1 3 6 4 5 2 5 6 2 3 4 1 Keypad Removable Top Cover Draft protection Drip tray grid Drip tray Front door ...

Page 13: ...2 3 4 1 General switch Adjustable cooler thermostat Ice bank inlet pipe joint Ø5 16 8 mm Inlet safety valve with check valve and mechanical filter Ø5 16 8 mm Ice bank drainage pipe CO2 inlet pipe Ø5 16 8 mm Adjustable boiler thermostat Boiler switch ...

Page 14: ...14 Rear View 1 2 2 1 IEC inlet power cord Support feet ...

Page 15: ...nsing button L 1 BLUE led STAND BY Quick flashing Little or no water at the inlet Slow flashing Little or no CO2 remaining only in FIZZ model L 2 GREEN led Static ENERGY SAVING mode active The water is dispensed while pressure is being applied to the button For safety reasons to dispense hot water hold down P 3 button first and then hold down P 4 button at the same time P 1 P 2 P 3 P 4 L 1 L 2 ...

Page 16: ...16 Technical Features Technical Data Plate 16 Year of manufacture 02 Month of manufacture 06049 Serial number ...

Page 17: ...TA FATTO APPROVATO VERIFICATO DISEGNATO 467mm 330mm 489mm NOME SE NON SPECIFICATO QUOTE IN MILLIMETRI FINITURA SUPERFICIE TOLLERANZE LINEARE ANGOLARE QUALITA FATTO APPROVATO VERIFICATO DISEGNATO 467 318 80 335 247 396 357 COMPANY NAME MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL ANGULAR MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL NAME DATE DRAWN CHECKED ENG APPR MFG APPR Q A COMMENT...

Page 18: ... Pump Professional membrane carbonation pump Condensation Ventilated Refrigerant gas HFC R290 Supply 230 V 50 Hz Compressor 1 10 HP Watts 1220 W 5 3 A Inlet water Pipe ø 8mm Inlet CO2 Pipe ø 8mm Dispensing area height He mm 269 Dimensions L x D x H mm 330x489x467 318x335x467 Packaging dimensions mm 400x570x540 360x360x650 Net weight kg 35 24 Gross weight kg 38 28 rated at a room temp of 25 C and i...

Page 19: ...rs is needed before turning it on so that the refrigeration circuit can function perfectly Ensure that a qualified technician connects it to the electric supply following the manufacturer s instructions and according to the local safety regulations The end user is not permitted to access the internal service parts of the unit Only technical personnel should carry out operations of this nature Inst...

Page 20: ...ragraph on page 29 Filling the Ice Bank In mod Wave Hot open the rear panel using the supplied key Fill the ice bank using the specific inlet pipe joint Ø5 16 8 mm 1 In mod Box 60 remove the top cover and pour water inside the dedicated hole 1 Stop filling the ice bank when water starts flow out the overflow pipe 2 Once you have filled the ice bank avoid moving the unit If you have to move the uni...

Page 21: ...r length in order to maintain the water inside fresh The machine comes with a non return valve 2 and a security valve 3 It s not included a water pressure reducer that must be assembled upstream the system Once the pipes are attached turn on the tap Ensure there are no leaks Before drinking the water from the system perform a thorough rinse of the circuit by dispensing water from each product line...

Page 22: ...n are now activated Press the Sparkling Water button on the right of the Wave Hot keypad 4 or on your chosen tap in order to release any air in the circuit and to allow the pump to fill the carbonator with water After around 1 2 minutes the sparkling water pump stops Chiller Thermostat The thermostat 2 is set in the maximum position to control the ice bank If you want to avoid the formation of ice...

Page 23: ...that the boiler is full with water Turn on the boiler switch and make sure the front panel is closed After around 1 2 minutes the water reaches the setted temperature Boiler Thermostat The thermostat 2 is set in the maximum position to control the boiler If you want to decrease the temperature of the hot outlet water turn the thermostat screw anti clockwise 1 2 CAUTION Hot water reaches 95 C Keep ...

Page 24: ...nder is not provided It s not possible to install CO2 cylinders inside the unit To increase or decrease the level of carbonation of the water you need to adjust the screw 1 Turning it clockwise increases the level of carbonation We recommend that you do not exceed 4 bars of pressure 2 To reduce the carbonation level turn the screw anti clockwise The level will decrease as soon as sparkling water i...

Page 25: ...er cylinders or surfaces dropping the cylinders or subjecting them to mechanical stress All of the above may compromise their integrity and resistance The cylinders must not be lifted by the cap or dragged rolled or slid along the floor Even if only being moved for short distances an appropriate hand cart or other suitable means of transport should be used Do not use magnetic lifters or slings wit...

Page 26: ...articles with dimensions of 0 5 microns and above It also reduces the levels of any contaminants such as asbestos fibres and micro organisms such as Cryptosporidium and Giardia It protects gaskets pumps tubes and valves against blockages corrosion and abrasions Approved by the Italian Ministry of Health and the Water Regulations Advisory Scheme UK it is certified compliant with the NSF ANSI standa...

Page 27: ...I 304 Electricity supply 220V 50Hz Power 12Wh Maximum water flow 5 litres min Minimum pressure 0 5 bar Maximum pressure 9 bar Radiation 30 000 µWs cm2 Green LED ON bulb is on Maximum duration of the bulb 8 000 hours 11 months The UV sterilizer is made entirely in Italy and complies with Italian and European quality and safety guidelines CAUTION The light emitted by the ultra violet lamp may cause ...

Page 28: ...f UV OUT pipe it s not necessary to turn the water off The UV OUT lamp can NOT be installed on the hot water nozzle Disposal of used UV OUT lamps The UV lamps contain mercury amalgam This allows the disposal of the lamps at a local waste management site This way of disposing is completely identical to the disposal of neon lamps or energy savings lamps These lamps are nevertheless registered under ...

Page 29: ... carried out by the BLUPURA Reseller or by qualified technical personnel who have completed specific training courses on hygiene and sanitization To sanitize the unit we recommend the use of hydrogen peroxide oxygenated water 5 diluted in drinking water Filter replacement and sanitization All of the operations must be carried out exclusively by qualified technical personnel To view the video tutor...

Page 30: ...urface of the steel Cleaning the drip tray When it is necessary to clean the drip tray use a diluted limescale cleaner citric acid or similar The drip tray can also be washed in the dishwasher Cleaning the dispensing nozzles On a daily basis spray a diluted hydrogen peroxide solution e g Cooler Clean onto the nozzles DO NOT USE a jet of water to clean the unit or detergents with abrasives Light sc...

Page 31: ...31 Service history Installation Technician Date Notes Signature Maintenance Technician Date Notes Signature ...

Page 32: ... warranty does not include normal wear and tear to the components or any damage caused to the components due to negligent or improper use or due to a non standard installation The warranty shall not be applicable if the unit has been tampered with or if repairs have been carried out by unauthorized persons For the conditions not specified here please refer to the Blupura Srl WARRANTY CONDITIONS Fo...

Page 33: ......

Page 34: ......

Page 35: ...160372 Rev 00 02 10 2017 15 40 ...

Page 36: ...Blupura srl Sede legale Via F lli Brancondi 56 60025 Loreto AN Italy Sede operativa Via Erideo Marinucci 2 4 62019 Recanati MC Italy Tel 071 9710080 Fax 071 9710084 info blupura com www blupura com ...