LAN-AD16f 

4.1.2

 

Operation 

In the left window of the program screen, all DAQ 
systems with a working network connection to the 
PC are listed displaying their serial number. The 
LAN-AD16f is displayed as "LAN-Base". 

When being connected to a network, the device 
automatically self-assigns (DHCP) a link-local ad-
dress. 

Select a network DAQ system to show the parame-
ters of this device in the TABs on the right.  

Settings can be modified by clicking the "Options" 
button.  

 

We strongly recommend using the automatically assigned configuration. Manual changes should only 
be done by a network administrator. 

 

4.1.3

 

Notes about TCP/IP 

Each participant of the network has his own IP address consisting of four groups of numbers. To guarantee 
that a data package arrives at the correct address, this IP address must have been given out only once.  

Each IP address contains the network number identifying the net your PC belongs to. Please make sure the 
PC and the LAN-AD16f are in the same net, i.e. they have the same network number, to be able to commu-
nicate with each other.  

 

4.1.4

 

Example configuration for the manual input of the network settings 

If there is only the PC and the DAQ system in your network (network number 

192.168.32.0

), you can use 

the following configuration. The IP address currently set in the PC is shown in the title bar of the  
LAN-AD16f Administration Utility: 

Configuration 

Value 

IP address PC (see chapter 4.1.5) 

192.168.32.1

 

IP address LAN-AD16f 

192.168.32.2

 

network mask 

255.255.255.0

 

 
 

4.1.5

 

Assign IP address of the PC 

 

The IP address of the PC and the netmask is entered via the 
Control Panel of the PC in the dialog "Internet Protocol 
(TCP/IP) Properties". Step by step click the following entries: 

Page 7 

Summary of Contents for LAN-AD16f

Page 1: ...each 1 counter Digital states are recorded or set at 16 digital in puts and outputs each Digital inputs are sampled time synchronously with the analog inputs One 19 bit counter accessible via the firs...

Page 2: ...bed in chapter 4 2 Connections and pin assignment Figure 1 2 1 Power supply The power supply of the DAQ system with 9 40V DC is connected at the 3 pin DIN plug on the back of the device The power supp...

Page 3: ...AOut 2 10 AIn 10 20 37 AGND The max potentials to ground must not exceed 12V Any channel overload may influence measure ments of other channels and may lead to wrong values The internal connection of...

Page 4: ...28 5V max 50mA 10 19 29 DGND The digital inputs and outputs are protected by serial resistors Input voltages beyond the permitted voltage range of 0V 5V can damage the device The counter of the LAN AD...

Page 5: ...or sets the input to low if no voltage is applied there In this regard please also see application ex amples of the optocoupler you use Optocoupler boards with 8 or 16 inputs are available at bmcm 3 2...

Page 6: ...ating program NV4 5 measuring software NextView 4 available in the Standalone versions Lite slim version with basic functions Pro full version with complete functional range Analysis version for the a...

Page 7: ...t the correct address this IP address must have been given out only once Each IP address contains the network number identifying the net your PC belongs to Please make sure the PC and the LAN AD16f ar...

Page 8: ...ndows is included on the product page of the LAN AD16f For further information about how to integrate the SDK in the program ming environment please see the corresponding programming manual UM LIBAD4...

Page 9: ...ee chapter 4 3 different versions Trial Lite Professional Analysis available German or English unlimited number of devices even of different type can be installed except for NextView 4 Lite configure...

Page 10: ...nned with 50kHz the total sampling rate adds up to 250kHz The values for accuracy always relate to the respective measuring range Errors might add at worst Analog outputs Output range Output current 2...

Reviews: