background image

meM-LOG-SE 

 

 

© BMC Messsysteme GmbH 

 

Page 9 

Software 

Software product 

Notes 

Documentation 

Device driver 
(USB) 

U

BMCM-DR

U

  

(driver package) 

1. install driver package to hard disc 
2. Windows

®

 Plug&Play installation  

U

BMCM-DR-IG

U

  

(driver installation manual) 

Operating 
program 

U

ST-meM-LOG SE

 

software to configure and operate the hardware, 
read out stored measurement data 

U

ST-meM-LOG SE

U

  

(user manual) 

U

NV4

 

measuring software NextView

®

4 (requires license 

number, no freeware!) to display and analyze 

lfx 

signal files created with ST-meM-LOG SE; 
stripped-down "Analysis" version provided  

 

U

NV4-DEMO

free demo version of NextView

®

U

NV4-IG

U

 (installation Stand-alone version) 

UU

NV4-UM

U

 (user manual) 

"First steps" in the NextView

®

4 demo pro-

ject (displayed at first start of the software)

 

7.1 Driver 

installation 

 

If connected to USB, a driver installation is required for 

meM-LOG-SE

 in contrast to a serial RS232 con-

nection. Only then additional software can be installed. To make sure that the installation is done correctly, 
please follow the instructions in the order as described below. 

7.1.1 

Install driver package 

The prior installation of the bmcm driver package 

U

BMCM-DR

U

 to the hard disc of your PC makes the driver search for 

Windows

®

 much easier. Especially in case of driver updates, only the new driver package has to be installed, the hard-

ware automatically uses the new version. The link to install the driver package is located on the 

meM-LOG-SE

 prod-

uct page of the "Software Collection"-CD.  

7.1.2 Plug&Play 

installation 

As soon as the 

meM-LOG-SE

 is connected to the PC, the system announces the new hardware. Start the automatic 

hardware detection by selecting the following option: 

-

 

Windows

®

 XP

"Install the software automatically" (SP2: do not connect with Windows

®

 Update!) 

-

 

Windows

®

 2000

:  "Search for a suitable driver for my device" 

Under Windows

®

 Vista, no selections have to be made. The driver is found and installed automatically upon connection 

of the hardware, because the driver package has been installed on hard disc before. For the same reason, no additional 
location needs to be entered for the driver search under Windows

®

 2000.  

7.1.3 Check 

installation 

In the Windows

®

 Device Manager, the entry "Data Acquisition (BMC Messsysteme GmbH)" is included after success-

ful installation displaying the installed bmcm hardware. To open the Device Manager, proceed as follows: 

-

 

Windows

®

 Vista

:  Start / Control Panel/ System / "Device Manager" 

-

 

Windows

®

 XP

Start / Control Panel / System / TAB "Hardware" / button "Device Manager" 

-

 

Windows

®

 2000

:  Start / Settings / Control Panel / System / TAB "Hardware" / button "Device Manager" 

Double click the 

meM-LOG-SE

 to open its properties. For general information, any existing device conflicts and pos-

sible sources of error see TAB "General". 

7.2  Installation of ST-meM-LOG SE and NextView

®

 

Install the operating program "ST-meM-LOG SE" for configuring and operating the data logger. The setup 
program is available on the product page of the 

meM-LOG-SE

. The device can be connected both via USB 

or via the serial interface (RS232).  

 

Install the demo version of the professional software NextView

®

4 for measurement data acquisition and 

processing to graphically display and analyze the signal files created with ST-meM-LOG SE. The setup 
program 

U

NV4-DEMO

U

 is available in the section "NextView

®

 4.x".  

When you open the software, you get first instructions about how to operate the program. For detailed information, an 
online help is provided. 

 

With NextView

®

4 DEMO, signals cannot be stored. The full version NextView

®

4 is no freeware and 

requires a license number! A stripped-down "Analysis" version is available. 

Summary of Contents for MEM-LOG-SE

Page 1: ... it is no problem to realize measuring applications which require mobility and flexibility in a high degree In order to extend the operating time of the accumu lator the device changes into an energy saving mode after 1 minute Sleep Mode and just wakes up occasionally e g shortly before scanning the next measuring value Via 16 analog input channels in the measuring range of 5V with a resolution of...

Page 2: ...ition and processing measuring files created with ST meM LOG SE can be dis played in NextView 4 as graphic signal curves and then be ana lyzed NextView 4 is also available as a stripped down Analysis version A free demo of the software is included with delivery The instruction set for program ming the meM LOG SE is com patible to the ADAM4000 series For further information please visit our homepag...

Page 3: ... each channel separately storage of either all channels to be saved or only of channels which are in state of alarm If measuring values are within their normal range again the scan is temporarily interrupted If not in Loop Mode see below the scan continues until memory is full or measurement is stopped even if a scan has been stopped with the device button it can be taken up again the new measurin...

Page 4: ...listed in the following table Pin Sub D15 meM LOG SE 1 Alarm Out H active high 9 Alarm Out L active low 8 15 Relay contact alarm 3 Digital In 1 active low 11 Digital In 2 active low 12 Scan start active low 5 13 Ground 2 4 6 7 10 14 n c In case of alarm the alarm outputs and the relay contact at pin 1 9 or 8 15 become active at the same time as long as the signal values exceed the defined range Al...

Page 5: ...ion over great distances connection of a modem 3 3 1 Serial connection RS232 The serial connection requires a 9 pole cross wired null modem cable not electrically isolated which is connected to the two 9 pole Sub D plugs of the logger and the PC to be ordered under ZUKA SER9 The serial connection of the logger is located at the back of the device If your PC only provides a 25 pole serial connectio...

Page 6: ...scan Æ turn off device measuring values are saved up until the point of turning off at least 5sec Scan running repeated and short flashing of LED fast flickering after 0 5sec after 5sec LED off Instant On temporarily inter rupt energy saving mode 0 5sec Sleep Mode not changing If you start a scan with the device button or a digital signal at the digital connector the memory must be empty This does...

Page 7: ... was put on user friendliness and reliability Administration of USB and the serial interface in one program The connection between PC and data logger is realized via the serial RS232 as well as the USB interface so that the advantages of both interfaces are available to the user see chapter 3 3 ST meM LOG SE manages both inter faces so that one device or several can be connected to USB and another...

Page 8: ... possible in all operating modes Store measuring data with different file format When reading out measuring data from the memory of the data logger ST meM LOG SE writes files in txt or lfx file format which can be displayed as table values and analyzed in various programs for word processing Notepad Wordpad Word etc and spreadsheet e g Excel Especially to mention is the storage as an lfx file the ...

Page 9: ... the software automatically SP2 do not connect with Windows Update Windows 2000 Search for a suitable driver for my device Under Windows Vista no selections have to be made The driver is found and installed automatically upon connection of the hardware because the driver package has been installed on hard disc before For the same reason no additional location needs to be entered for the driver sea...

Page 10: ...0Hz channel Sampling period 18h 12min 15sec 1sec in steps of sec 10min 55sec 350msec 0 01sec in steps of 1 100 sec Total sampling rate 16Hz 1 6kHz The total sampling rate is the sum of the sampling rates of the individual used channels e g 5 channels à 100Hz 500Hz total sam pling rate The values for accuracy always relate to the respective measuring range Errors might add at worst Digital inputs a...

Reviews: