6.3 Spindle connection at screw terminals
PE
Earth Protection GND
PE
Earth Protection GND
U
Spindle Phase 1
V
Spindle Phase 2
W
Spindle Phase 3
SGND Signal-GND for FP- and PTC-Signals
FP
Hall-Sensor-Signal
(Spindle
speed)
PTC
PTC-Signal
(Spindle
Temperature)
6.4 Mains
Control cables, supply cables and motor cables must be isolated
from each other. Shielded cables are to be preferred !
6.3 RS232
(D-Sub 9pin male)
Pin
Description
Function
2
RxD
receive-data (data to converter)
3
TxD
send-data (data from converter)
5 GND
Ground
use a standard zero-modem-cable for connection to PC
PE
PE
U
V
PTC
FP SGND
W
-
-
1
3
4
5
6
2
L1
N
PE
L1 Mains L1
N Neutral N
PE Earth Protection GND