background image

 

4. Method 2

Automatic cutting specimen 

1) Fix the specimen between the anvils of cutting chamber to pinching screw on the “L” tongs and clamp the specimen with 
hand, and retighten the screw. 
2) Select cutting speed. Turn on the power switch and choose right speed by pressing the cutting speed setting button until 
the LCD indicates the selected speed. 
3) Press “auto/manual” button to choose auto mode. 
4)  Rotate  the  hand-wheel  of  cutting  chamber,  the  abrasive  disc  contact  the  specimen,  but  not  let  the  disc  contact  the 
specimen. 
5) Press the “start” button to start the motor, then the machine will cut the specimen automatically. Press the “pump” button 
to cool down the specimen during the cutting process. 
6) After cutting is completed, press the “withdraw” button, then the cutting motor stops cutting and step motor is actuated to 
withdraw the tools. 
7) In cases the operator is not present in the process of cutting, it will stop automatically and withdraw the tools at the end 
of cutting operation. 

5. Method 3

Cutting the specimen manually   

1) Press “power” button to turn on the power. 
2) Press the “auto/manual” button to select manual mode. 
3) Fix the specimen as per Article 1of Method 2. 
4) Press “start” button to start up cut-off motor. 
5) Press the “pump” button to start up coolant. 
6) Rotate left – handed wheel to start cutting manually 
7) At the end of cutting operation, withdraw the abrasive disc to original position. 

6. Maintenance and safety notes: 

1) The power of this machine is of three phases and four cords plug. The power socket must be grounded. 
2) The water pipe should be free from leakage and block out. 
3) Clean and maintain the machine in time at the end of shift. 
4) Should any abnormal noise be heard, stop the machine immediately 
5) Must install reliably meets the grounding 

Cautions: 

Power must be turned off prior to specimen clamping. 
Power socket in connection with the machine must have zero line. 
The  operator  must  not  leave  the  machine  when  cutting  the  specimens.  Should  any  abnormal  noise  be  heard,  stop  the 
machine immediately. 

Summary of Contents for BULUCUT-6

Page 1: ...ING MACHINE BMS Bulut Makina Sanayi ve Ticaret Ltd Şti Kocaeli KOBİ Organize Sanayi Bölgesi Köseler Mahallesi 6 Cadde No 20 2 Dilovası KOCAELİ TURKEY Phone 90 262 502 97 73 76 90 262 503 06 51 Web www bulutmak com e mail bms bulutmak com OPERATIONAL MANUAL ...

Page 2: ...CAUTIONS SAFETY NOTE 3 1 Descriptions 4 2 Technical parameter 4 3 Method 1 4 4 Method 2 Automatic cutting specimen 5 5 Method 3 Cutting the specimen manually 5 6 Maintenance and safety notes 5 Cautions 5 ...

Page 3: ... the machine onto unstable table Otherwise serious injury may happen when falling down in case Nothing is allowed to put on the machine Don t overload the power socket in case of fire hazard or electric shock Don t try to dismantle the machine to prevent from electric shock Only qualified maintenance technicians are allowed to repair the machine You will be exposed to dangerous voltage or other da...

Page 4: ...ically or manually Its large capacity cutting chamber facilitates its operation It is one of the specimen making equipment s necessary for metallographic test in colleges and factories Super large cutting chamber 2 Technical parameter 1 Power 220V 50Hz 2 Rotating speed of abrasive disc 2100 rpm 3 Specification of abrasive disc 350mm 2 5mm 32mm 4 Max Cutting diameter φ80mm 5 Max cutting capacity 80...

Page 5: ...l stop automatically and withdraw the tools at the end of cutting operation 5 Method 3 Cutting the specimen manually 1 Press power button to turn on the power 2 Press the auto manual button to select manual mode 3 Fix the specimen as per Article 1of Method 2 4 Press start button to start up cut off motor 5 Press the pump button to start up coolant 6 Rotate left handed wheel to start cutting manual...

Reviews: