Cleaning
8
Cleaning the machine
8.5
121
8.5.2
Cleaning the mixing and delivery vessel
1.
Switch the machine off via the "Control unit on" switch.
2.
Secure the machine against restarting To do this, disconnect a battery
contact.
3.
Open the dome cover (see Section 7.7.6).
4.
Lift up the dome screen and swivel it to the side.
5.
Remove adhering residual material from the entire mixing and feed
tank.
6.
Clean the vessel vent.
7.
Rinse the vessel vent with plenty of water.
8.
Rinse the mixing and delivery vessel with plenty of water.
9.
Remove the material residues from the mixing shaft seals at the front
and rear.
10. After cleaning, grease the lubrication points on the mixing and delivery
vessel, the dome cover and the vessel ventilation.
8.5.3
Cleaning the upper and lower air
The upper air and lower air hoses as well as the connections may be
contaminated by material residues. At the end of work and during longer
interruptions, the upper air and lower air hoses and their connections must
be cleaned.
1.
Switch the machine off via the "Control unit on" switch.
2.
Secure the machine against restarting To do this, disconnect a battery
contact.
Figure 62: Cleaning the air hoses
3.
Loosen the hose coupling of the upper and lower air hoses (1) and (2)
on the mixing and delivery vessel.
Summary of Contents for alpha CR
Page 6: ...Contents ...
Page 180: ...14 Appendix 14 1 Declaration of conformity 180 14 1 Declaration of conformity ...
Page 181: ...Appendix 14 Drawings 14 2 181 14 2 Drawings 14 2 1 BMS alpha CR standard ...
Page 182: ...14 Appendix 14 2 Drawings 182 14 2 2 BMS alpha CR B feeder ...
Page 183: ...Appendix 14 Drawings 14 2 183 14 2 3 BMS alpha CR B S feeder scraper ...
Page 185: ...Appendix 14 Circuit diagrams 14 3 185 ...
Page 186: ...14 Appendix 14 3 Circuit diagrams 186 ...