 4. OPERATION  

 

Note: 

The  infrared  lamp  in  this  heater  is  fragile  as  such  it  is  important  that  it  is  not  subjected  to  any  unnecessary  shocks  or 

vibration and is not moved when it is in use. Wait till the heater has cooled down before moving.

 

WARNING! 

Ensure you read, understand and apply the safety instructions in Section 1 before using the heater.

 

4.1     Ensure the heater is at least 1000mm from any object. The heater can be tilted from 45° to 90° set it to the required angle 

before switching the heater on. Adjust the heater angle by loosening the two bolts on the wall mounting bracket. Tighten the 
bolts again when the desired angle is reached.

 

4.2     Ensure that the mains supply is adequately protected and that the mounting bracket is earthed, then switch on.

 

4.3     Make  sure  the  heater  is  disconnected  from  the  mains  supply  before  any  cleaning  is  attempted.  Also  allow  the  heater  to 

cool completely.

 

4.4    When the heater is no longer required, switch off and if possible unplug the unit.

 

4.5     Clean the exterior with a soft damp cloth.

 

4.6     To replace the lamp, contact your authorized dealer.

 

4.7     The mains lead is made from high temperature cable, not a standard PVC cable and as such should not be replaced without 

consulting a suitable qualified electrician.

 

 

 
 

 5. MAINTENANCE  

 

 

Note: 

Before examining  or carrying  out  any maintenance  ensure the  heater  has cooled  down  and  is disconnected from  the mains 

supply.

 

 

5.1 

The heater contains no moving parts  and therefore very little maintenance is required other than to ensure that  there is no 
excessive build-up of dust/dirt  on the reflectors  or emitters as this can cause overheating and premature emitter failure.  To 
clean the appliance, turn off and disconnect from mains supply, allow to cool then wipe with a damp cloth. 

 
 

 

 6. LAMP REPLACEMENT  

 

 

Note: 

Before examining or carrying out  any maintenance ensure the heater  has cooled down and is disconnected from the mains 

supply. 

 

The lamp used in the fitting is robust and if knocks and shock vibrations are avoided, will last for around 5000 hours. 

 

6.1

  TO REPLACE THE LAMP

 

 

a)   Disconnect  the  heater  from  the  power  supply  by  unplugging  from  the  mains  socket  and  wait  until  the  body  has 

cooled down. 

b)   Remove the front guard 4 x M3 screws 
c)    Remove the screws on the back spline and pull away from the fitting. 
d)   Unclip the lamp from the spring clips at each end, allowing the lamp to move forward clear of the back reflector.  
e)    Disconnect the lamp wires from the terminals located in the electrical box on the rear of the heater, and then remove the 

lamp. 

f)   Insert  the  wires  of  the  new  lamp  through  the  holes  in  the  heater  body  to  the  electrical  box  and  reconnect  them  into  the 

terminals. Ensure that the terminals are tightened correctly to make a good electrical connection. 

g)   Re-assemble making sure all the parts are replaced and the guard is in position. 

 

   

WARNING! 

Failure to reassemble all the parts and use the guard  will invalidate any remaining guarantee and may make the 

unit dangerous. 

 

 
 

 7. SPARES  

 

 

Note: 

Spare are available from your distributer 

 

Please quote the following Lamp codes when requesting spares 

 

 

 
 

 
 
 
 
 
 
 

Part Ref. 

Description 

RL15GH 

Lamp 

– 1.5KW 220-240V Glare Reduction Lamp 

Summary of Contents for HB-1500

Page 1: ... without consulting a suitable qualified electrician Ensure that the mounting bracket is adequately earthed Use of an extension cord is not recommended 1 2 GENERAL SAFETY INSTRUCTIONS Remove all packaging and store it away from children check the package and heater for visible damage or tampering Familiarize yourself with the applications and limitations of the heater Ensure the heater is in good ...

Page 2: ... placed 3 1 3 Use the bracket as a template Fix the metal bracket to the wall by means of the three holes and appropriate fixings not supplied 3 1 4 Refit the heater back onto the bracket and secure with the two bolts 3 1 5 Adjust the angle of heater to direct heat where required between 45 and 90 see fig 1 3 2 PARASOL MOUNTING Ensure the heater is at least 500mm away from the canvas material of t...

Page 3: ...little maintenance is required other than to ensure that there is no excessive build up of dust dirt on the reflectors or emitters as this can cause overheating and premature emitter failure To clean the appliance turn off and disconnect from mains supply allow to cool then wipe with a damp cloth 6 LAMP REPLACEMENT Note Before examining or carrying out any maintenance ensure the heater has cooled ...

Page 4: ...riate channels at the end of its useful life Failure to do so may incur the penalties established by laws governing waste disposal BN Thermic Ltd Stephenson way Three Bridges Crawley RH10 1TN Tel 44 0 1293 547361 Fax 44 0 1293531432 Email sales bnthermic co uk Web www bnthermic co uk NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications...

Reviews: