background image

1. Place Counter Gasket

over mounting hole

to align with profile of

dispenser.

2. Insert Stem with tube

and all Fiber Optic Cables

carefully through mounting

hole.

3. Place the Wave Washer

on top of the Mounting

Nut Install Mounting Nut 

on Stem and thread 

upwards. (Minimum 2-1/4" 

(55mm) diameter 

clearance needed below 

mounting nut).

NOTE: 

The outer diameter of 

the Mounting Nut may need 

to be filed down if space

 

under the counter is tight.

NOTE: 

Make sure Fiber 

Optic Cables and Tubing are 

INSIDE

 Mounting Nut. Do not 

tighten completely until end of 

installation.

5. Attach the tubing to

the top barb of the

Foam Mixer Housing.

6. The Bottle Cap can only

be placed onto the Stem

in one orientation.

The flat section on the

Stem is to be aligned with 

the flat section on the

Bottle Cap.

7. Rotate the Bottle back

and forth to align the flat

section of the Stem to the 

 

flat section on the Bottle.

8.  Push the Bottle Assembly 

up onto the Stem while

also inserting the Foam

Mixer Housing into the

hole in the post on the

Bottle Cap.

Fully insert the Bottle

Assembly over the Stem

until it stops. Both red

o-rings must be inside the 

Bottle Cap.

9. While pushing upwards

on the Bottle, Thread

the Stem Locking Nut

down onto the Bottle

Cap threads

NOTE: 

After assembly, hold 

the Stem and lightly rotate 

the Bottle back and forth 

and tug down to be sure it is 

on tight. If it is loose, repeat 

Steps 7 and 8.

NOTE: 

Tug Tubing on 

Foam Mixer Housing down 

from under the counter to 

straighten out the tubing.

10. Connect the small

diameter tube from the

Foam Mixer Housing

to the air tube adapter

located on the Bottom

Housing.

11. Thread Fiber Optic

Connector Tip into

Bottom Housing. Keyed

feature on Connector

Tip ensures Fiber Optic

Cables are always

located correctly.

13. Align the Top Assembly

above the counter to

the desired position

and tighten the

Mounting Nut against

the bottom of counter

so the Top Assembly

does not easily rotate.

Make sure Fiber Optic

Cables are not between 

the underside of the

counter and top of

Mounting Nut. See

Steps 3 and 4.

14. Plug AC Adapter into

wall and other end into

Bottom Housing base.

Installation:

Filling Instructions:

 (use foam soap only) 

Unit will dispense commercially Marketed Bulk Foam Soap.
1. Insert tip of BobKey provided into opening of concealed locking mechanism to disengage door.

2. Door will disengage and rotate clockwise for filling from the top.

3. Fill dispenser with commercially marketed bulk foam hand soap 

(Do not use liquid or lotion soap).

4. Close door counter-clockwise to lock in place.

Replacement Parts List

Part Name 

Part No.

- A/C Adapter

3974-57

- International AC Adapter Plug Kit 

(U. K., Europe, Australia)

3974-58

- Mack Gasket Kit

824-167

 

(To secure Top Assembly under the counter due to irregular counter surface)

- External A/C Multi Adapter Kit

82

4

-201

- Nozzle Tip Replacement Kit Foam

828-310

- D Size Battery Pack 

(Batteries not included)

824-241

- Foam Mixer Housing

828-322

- Installation Hardware Packet with Foam Mixer Housing

828-443

(Includes Wave Washer, Counter Gasket, Mounting Nut, BobKey, Stem Locking Nut)

- Top Housing Assembly Foam

828-525

(Includes Installation Hardware Packet and Foam Mixer Housing)

- Bottom Housing Assembly Foam

828-550

TOP FILL ONLY !

4. Thread the Stem Locking

Nut onto the Stem. The

ribs on the Nut are to be

towards the top. Once

it goes past the two

red o-rings, the nut will

automatically stop

threading.

Apply a bead of Silicone  

around the base of the  

Top  Housing  above  the        

counter to prevent  

spilled soap from going  

through the mounting   

hole.

12. Thread Fiber Optic Nut

onto Connector Port

and hand snug only.

Do not over-tighten.

NOTE: DO NOT bend or 

kink Fiber Optic Cables.

3

2

Summary of Contents for B-828

Page 1: ... using appropriate hole saw For granite marble counters recommend using a diamond hole saw consultwithstoneandgranitespecialist Ifneeded mountingholeshouldbeoffsettoclearthesinkrim TheMountingnutrequires 2 1 4 57mm diameter clearance directly below the counter To Operate Troubleshooting 1 Soap dispenser does not dispense soap but you can hear motor running The green LED lights up when hands are un...

Page 2: ...s located correctly 13 Align the Top Assembly above the counter to the desired position and tighten the Mounting Nut against the bottom of counter so the Top Assembly does not easily rotate Make sure Fiber Optic Cablesarenotbetween the underside of the counter and top of Mounting Nut See Steps 3 and 4 14 Plug AC Adapter into wall and other end into Bottom Housing base Installation Filling Instruct...

Page 3: ...dels B 824 B 850 B 852 B 855 B 856 B 858 Liquid B 828 B 840 B 842 B 845 B 846 B 848 Foam Required Clearances Mounting Hole 1 3 8 35mm diameter Maximum Counter Thickness 2 50mm Below Counter 18 457mm vertical clearance 5 127mm diameter directly below mounting hole for bottle and bottom housing 2 1 4 57mm diameter needed for mounting nut directly below mounting hole If sink rim below the counter is ...

Page 4: ...to 3 64 to 76mm from Sink Rim to center of Mounting Hole 6 152mm 7 178mm Drill 1 3 8 35mm Diameter Hole 7 178mm 8 203mm Recommemded Mounting Distance to Finish Face of Wall Between 6 to 8 154 to 203mm 2 1 2 to 3 64 to 76mm from Sink Rim to center of Mounting Hole RIGHT SIDE MOUNTING TEMPLATE LEFT SIDE View from Top of Counter View from Top of Counter ...

Reviews: