3-2
3.3.4
Remove the four bolts and washers (7/16-inch) that secure the coil bed to the cabinet.
3.3.5
Remove the coil bed assembly by carefully lifting it up.
3.3.6
Disconnect the two Molex connectors that are connected to the coil bed assembly.
Please Note: Remove with care. Sensors are easlily broken.
3.3.7
Remove the clip using needle nose pliers or a small screwdriver.
Please Note: Make note of the order of the washers on the top and bottom of the shaft.
Figure 3.4
Figure 3.4
Figure 3.5
Sensors
Connectors
Figure 3.6
Figure 3.7