12
D
GB
F
E
I
Electrical system
Make connection of the compressor motor according to the circuit diagram (see
inside of terminal box). Comply with local safety regulations for electrical work and
the safety standards EN 60204, EN 60335 when connecting.
For cable lead-through at the terminal box use suitable cable screw connections in
correct protective version (see name plate). Use strain relief. Avoid abrasion points on
cables.
Motor contactors, feed lines and fuses are to be rated according to the maxi-
mum operating current (see compressor nameplate).
Compare the details for voltage and frequency on the nameplate with the details for
the electricity mains supply.
The motor may only be connected up when these
details correspond.
Electrical connection
High voltage! Perform work only with the electrical installation
disconnected from the power supply!
Electrical connections