22
8.1 Time synchronisation menu
To configure the time synchronisation of the SIGMA, validate the option in the
technician menu with the
key,
The following screen is displayed :
Select the time synchronisation mode from
the following options:
DCF Radio
,
Minute radio
(mode used for countries receiving the DCF radio signal
but for which the time is different from Paris/Berlin [only minute is
synchronised, date and hour must be set manually]),
EXTERNAL
(mode used for synchronisation from a Sigma “Master”
which transmits a GPS signal simulation from an ASCII extension card),
NONE
: if you choose to have no synchronisation, the radio pictogram is
not displayed.
GPS
,
Remark : all the synchronisation options are proposed without checking
that an antenna is connected (by default, the configuration is DCF
mode).
In case of synchronisation input failure, an alarm message is sent. This
alarm is triggered after 24 hours without synchronisation.
Select the synchronisation mode with the
and
keys and validate with
the
key.
The following screen is displayed if “Prog”
mode has been validated in the customer
menu (see “Time and date”, page
19) :
This menu can be used to program non-standard winter/summer time
changeovers.
Time synchro ok
Time outputs õ
Synchro:EXTERNAL ú
ok
Prog. time change:Yesú
ok