8
>
AFNOR option card (IRIG B 127), ref. 907940.
>
The A and B outputs can be used to assign two separate time zones via the web server.
>
The power supply can be used to power a maximum of two Bodet DHF V1 transmitters.
>
A maximum of four AFNOR option cards may be installed.
>
CURRENT LOOP option card, ref. 907944.
>
This option card makes it possible to :
- Simulate a DCF signal for the synchronisation of equipment using the 4-20mA DCF
- Synchronise Netsilon in 4-20mA ALS162 with an ALS162 antenna (product code: 907025)
>
Just one CURRENT LOOP option card may be installed.
>
PULSE option card, ref. 907942.
>
A maximum of four PULSE option cards may be installed.
The IMPULSE option cards 2, 3 and 4 are powered in parallel as illustrated below.
>
Wiring the second PULSE option card:
1) Wire the internal power supply
2) Configure the DIPs as shown opposite.
Wire one power supply at a time
onto the PULSE option card.
This option card can send the
impulses generated from the
internal 24V voltage or from
external 20 to 50 VDC source.