11) Installation examples
11.1 Set the 24V impulse output
Connect the 24V impulse clock line to the terminals 14 and 15.
Switch on the SIGMA.
Access to the technician menu (see
page 14).
Access to the menu “Time outputs”.
Use the navigation keys to :
–
Select the type of distribution (minute, 1/2 minute, second),
–
Enter the impulse duration,
–
Enter the time indicated by the slave clocks.
Select Start” and validate with the key
.
11.2 Set the DHF output
Connect the DHF transmitter to the DHF output (see page 27).
Switch on the SIGMA.
Access to the technician menu (see
page 14).
Access to the menu “Time outputs".
Use the navigation keys to :
–
Select the transmission power (25, 125 or 500mW),
–
Select the transmission channel (see DHF transmitter
instructions),
–
Set the SIGMA to “Init” mode,
–
When the clocks are synchronised, set the DHF output of the
SIGMA to “Start” mode (automatic return from “Init” to “Start”
mode after 4 hours).
Validate with the key
.
31
Impuls 01:MIN 1.2s ú
START 00:00 P+ ok
DHF 03 : INIT ú
125mW chan
nel:1 ok