background image

Body Clock Health Care Ltd

108 George Lane, South Woodford

London E18 1AD

Tel (+44) (0)20 8532 9595

Fax (+44) (0)20 8532 9551

www.bodyclock.co.uk

e-mail customercare@bodyclock.co.uk

0120

July 2010 (2) 

ISO 9001:2008   ISO 13485:2003

EC DIRECTIVE 93/42/EEC Annex V

Bodyclock Sensatone Inst 3.qx8_Bodyclock Sensatone Instr  14/07/2010  11:26  Page 12

Summary of Contents for SensaTONE

Page 1: ...SensaTONE Instructions for use TM Bodyclock Sensatone Inst 3 qx8_Bodyclock Sensatone Instr 14 07 ...

Page 2: ...rs from some form of incontinence during her life It can occur at any time most commonly after childbirth The severity of incontinence can vary Before you use the SensaTONE it is important that you read this manual carefully it contains all the information you need to ensure you are using the unit safely and correctly Explanation of Symbols on Unit Equipment providing a particular degree of protec...

Page 3: ...heir Meanings 5 Additional Functions 5 Setting up Your SensaTONE 6 Useful Diagrams 7 Using Your SensaTONE for PFS 8 Choosing the Right PFS Mode 9 Frequency of Use 9 Using Mode D After Care 9 PFS FAQ s 10 Technical Specification 11 3 Bodyclock Sensatone Inst 3 qx8_Bodyclock Sensatone Instr 14 07 ...

Page 4: ...y Clock Health Care on 44 0 20 8532 9595 General Precautions 1 Do NOT use this unit without first reading these instructions 2 Do NOT immerse the SensaTONE in any liquid 3 Do NOT place it close to any source of excessive heat or operate it in the presence of flammable gas 4 Do NOT drop this unit onto a hard surface 5 Do NOT attempt to dismantle the SensaTONE 7 Only use specified batteries and elec...

Page 5: ...ser Display Additional Functions Load Detector If the vaginal probe becomes detached the intensity will drop back to zero Low Battery Indicator A flashing battery symbol will be shown on the display Automatic Power Off When the unit intensity levels are zero and the SensaTONE has not been in use for about 5 minutes the unit will shut off automatically Indicates the mode in use Indicates the intens...

Page 6: ...ng water Liberally wash the probe using the same method but do not soak Rinse all soap and residue from hands and probe Dry the probe with a clean cloth paper towel and allow to air dry 5 Ensure that the SensaTONE is switched off 6 Insert the end of the leadwire into the socket at the bottom of the SensaTONE Connect the other end of the leadwire to the probe See diagram i on page 7 7 Apply a thin ...

Page 7: ...e purchased from Body Clock It may be re used by the same patient Wash as instructed before each use Do NOT use if the pack is open or damaged 7 pelvic floor muscle urethra vagina anus Diagram i Diagram ii probe Useful Diagrams Bodyclock Sensatone Inst 3 qx8_Bodyclock Sensatone Instr 14 07 ...

Page 8: ...s the intensity down key minimise the feeling f Modes A B and C all have fixed programme times The SensaTONE will automatically switch off once the programme is complete Mode D does not have a fixed programme time Refer to page 9 for more information about Mode D g After use always remember to ensure that the SensaTONE is switched off Remove the SensaTONE probe from your body disconnect the leads ...

Page 9: ...OT EXCEED TREATMENT TIMES UNLESS ADVISED BY A MEDICAL PROFESSIONAL Using Mode D After Care This is an optional Mode and can be used as follows Directly after treatment with the SensaTONE provided you are not experiencing any muscle fatigue As a maintenance mode after you have been using the sensatone on a regular basis and have experienced an improvement in your condition Please note that there is...

Page 10: ...notice a difference within 21 days Q What does it feel like A All three PFS programmes feel slightly different In general the feeling is that of a pleasant tingly squeezing sensation that contracts and relaxes the pelvic floor muscles Q Is it suitable for use by all women A Yes all women can use it provided none of the contraindications apply Q Can I use it whilst I m pregnant A No not until 12 we...

Page 11: ... 10 Hz in 4 secs and then back to 2Hz in another 4 secs Total cycle 8 secs Total time 45 mins After Care D All outputs have 200µs pulse width For the Urge Stress and Mixed mode the output pulses are alternatively switched on and off for 5 seconds Specifications Output Channel Single Channel Output Waveform Bi phasic rectangular Output Voltage 0 40V adjustable in 14 steps across a 500 ohm load Outp...

Page 12: ...rd London E18 1AD Tel 44 0 20 8532 9595 Fax 44 0 20 8532 9551 www bodyclock co uk e mail customercare bodyclock co uk 0120 July 2010 2 ISO 9001 2008 ISO 13485 2003 EC DIRECTIVE 93 42 EEC Annex V Bodyclock Sensatone Inst 3 qx8_Bodyclock Sensatone Instr 14 07 ...

Reviews: