background image

!

Revision!1.1!+!Dec!5,13!

57 

Error 57 is caused by an 

Open Circuit detected from 

the Drive Motor on the MCB 

(ONLY found on units 

manufactured 

AFTER

 Feb, 

2013. On units 

manufactured before Feb, 

2013, this error would show 

as an Error 52.) 

Check the motor wires (+ & -) are correctly attached to the MCB. 

Check if the motor brushes are touching the commutator. Are they worn? If so, clean with fine 

sandpaper and reinsert. Test. You may need to replace the motor brushes. Use a 9V battery to test the 

motor. Remove the Drive Belt that is connected to the Drive Motor Pulley and place the motor wires on 

the battery terminals, the motor should spin. The motor will not spin if you have not removed the Drive 

Belt. 

Check the resistance of the motor by using a Multimeter. Place one pin in each motor wire connector. 

You should get a reading between 1 & 2 OHMS. If you get an extremely high reading on the Multimeter 

or the letters “OL” (Overload), there is a problem with the motor. 

100 

Standard Code for an 

unrecognizable Error from 

the MCB  

No diagnosis possible – Change Motor Control Board 

!

Summary of Contents for T460XC

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...sor light flashes when you turn the motor but Error 53 still immediately appears when the treadmill is turned on it could be the R64 resistor on the MCB ROM PC Self Check error EPROM is correctly inst...

Page 9: ...se Put Safety Key appears on the Display then check the Reed Switch wiring is connected correctly to the Display If the wiring is connected correctly then check the Reed Switch is in the correct posit...

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ...the connection at the MCB which can get dusty If the connections are OK then most of the time it is a problem with a pinched Data Cable that has damaged one of the two communication wires inside Data...

Page 15: ...an 0 9 or up to 4 ohms If you get OL Overload on the multimeter then you have an open circuit in the motor and will likely have it in every position you try to take a reading The above mentioned Quick...

Page 16: ...then the Speed Sensor LED on the MCB will flash as it takes a reading between each segment of the optic disc 54 The Relay on the MCB is signaling that it is closed when it should be open Defective Rel...

Page 17: ...ace the motor brushes Use a 9V battery to test the motor Remove the Drive Belt that is connected to the Drive Motor Pulley and place the motor wires on the battery terminals the motor should spin The...

Page 18: ...turn the right rear roller screw B counter clockwise to allow the belt to track to the right and towards the centre If the running belt is tracking moving to the right turn the left rear roller screw...

Page 19: ...LEVATION CALBRATION is on screen 4 Press the Just Go key twice to begin the Elevation Calibration 5 Once you see COMPLETE on the display press the Stop key 4 times to return to the Welcome Screen Your...