background image

5

The Device Controls

Attaching the Lead Wires

SLIDE COVER

A cover conceals the controls for Mode, Time, Width, and Rate. Press the front of the 
cover and pull down in order to open the cover.

AMPLITUDE CONTROLS 

The Amplitude Control knobs are located on the top of the unit. The Amplitude Control 
knobs function as ON/OFF controls and adjust the intensity of the stimulation.

MODE 

The Mode switch is used to select and set the type of treatment utilized. The three modes 
available are: Burst (B); Continuous (C); and Modulation (M).

TIME

Treatment time can be set with the Time switch. There are two programs of fixed 
duration for 30- and 60-minutes and one program of continuous output. Press the Time 
switch until the desired position is engaged.

WIDTH 

The Width dial regulates the width of the pulse for both channels.

RATE 

The Rate dial regulates the number of pulses per second for both channels.

Insert the lead wires into the output receptacle located on top of the unit by holding the 
insulated portion of the connector and pushing the plug end of the wire into one of the jacks. 
After connecting the wires to the unit, attach each wire to an electrode. Lead wires provided 
with the device are compliant with mandatory compliance standards as set forth by the FDA. 

Note: Use caution when you plug and unplug the wires. Pulling on the lead wire instead of 
the insulated connector may cause wire breakage.

Caution: Never insert the plug of the lead wire into an AC power supply socket.

Summary of Contents for ZZA250

Page 1: ...ENGLISH READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE Instruction Manual Transcutaneous Electrical Nerve Stimulator TENS Reorder Number ZZA250...

Page 2: ...Warnings and Precautions 2 About the Device 4 The Device Controls 5 Attaching the Lead Wires 5 Electrode Selection and Care 6 Connecting the Device 6 Battery Information 7 Changing the Battery 7 Clea...

Page 3: ...t 4 Electrodes 1 pack Carrying case 9 Volt battery 2 lead wires Operation manual If you are missing any of these items please contact BodyMed at 1 866 528 2152 before using the unit System Components...

Page 4: ...d by a physician or licensed practitioner CONTRAINDICATIONS Any electrode placement that applies current to the carotid sinus neck region The use of TENS whenever pain syndromes are undiagnosed until...

Page 5: ...eness is highly dependent upon instruction from a person qualified in pain management using TENS If the device treatment becomes ineffective or unpleasant stimulation should be discontinued until re e...

Page 6: ...POSE ALL SUCH WARRANTIES BEING HEREBY EXPRESSLY EXCLUDED The device offers two controllable output channels This device creates electrical impulses whose amplitude duration and modulation can be alter...

Page 7: ...and one program of continuous output Press the Time switch until the desired position is engaged WIDTH The Width dial regulates the width of the pulse for both channels RATE The Rate dial regulates t...

Page 8: ...ter rinse well and blot dry thoroughly Any excess hair should be clipped not shaved to ensure good electrode contact with the skin You may choose to use a skin treatment or preparation that is recomme...

Page 9: ...persist stop treatment and contact your physician or licensed practitioner A 9 volt disposable battery is provided with the unit When the indicator light is dimming the battery has become too weak to...

Page 10: ...the battery If the indicator light is not on when the unit is turned on replace the battery and recheck 2 If the intensity has been adjusted and there is no stimulation check that the lead wires are p...

Page 11: ...nd intensity are adjustable M Modulated Width Pulse width is automatically varied in a six second interval The modulation range of pulse width is from setting value to 35 less than the control setting...

Page 12: ...Distributed by BodyMed Hudson Ohio 44236 1 866 528 2152 Made in Taiwan Reorder Number ZZA250...

Reviews: