Your physician or licensed practitioner should decide which type of electrode is best 
for your condition. Follow application procedures outlined in electrode packaging to 
maintain stimulation and prevent skin irritation. The packaging will provide instructions 
for care, maintenance and proper storage of the electrodes.

Be sure to use the electrodes provided by BodyMed

®

 and/or similar FDA legally 

marketed electrodes that are the same size, or larger than, the electrodes that are 
provided with this BodyMed

®

 TENS unit.

Electrode Selection and Care

Connecting the Device

IMPORTANT: 

Be sure both Amplitude Control knobs for Channel 1 and 2 are turned to the 

OFF position before connecting the device.

1.  Prepare the Skin: Always clean the electrode site with mild soap and water, rinse  
 

well and blot dry thoroughly. Any excess hair should be clipped (not shaved) to  

 

ensure good electrode contact with the skin. You may choose to use a skin treatment  

 

or preparation that is recommended by your physician or licensed practitioner.  

 

This will reduce the chance of skin irritation and extend the life of the electrodes.

2.  Connect the lead wires to the electrodes before applying the electrodes to the skin.

3.  Place the electrodes on the skin as recommended by your physician or licensed  
 

practitioner. Avoid excessive stretching of the skin when applying electrodes. This is  

 

best accomplished by applying the electrode and smoothly pressing it in place from  

 

the center outward.

4.  Insert lead wire connector to device: Plug end of lead wire into the channel output  
 

receptacle to be used, pushing plug in as far as it will go.

5.  Select treatment settings: Check that the unit is set to the proper settings as  
 

recommended by your physician or licensed practitioner.

Summary of Contents for ZZA250

Page 1: ...ENGLISH READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE Instruction Manual Transcutaneous Electrical Nerve Stimulator TENS Reorder Number ZZA250...

Page 2: ...Warnings and Precautions 2 About the Device 4 The Device Controls 5 Attaching the Lead Wires 5 Electrode Selection and Care 6 Connecting the Device 6 Battery Information 7 Changing the Battery 7 Clea...

Page 3: ...t 4 Electrodes 1 pack Carrying case 9 Volt battery 2 lead wires Operation manual If you are missing any of these items please contact BodyMed at 1 866 528 2152 before using the unit System Components...

Page 4: ...d by a physician or licensed practitioner CONTRAINDICATIONS Any electrode placement that applies current to the carotid sinus neck region The use of TENS whenever pain syndromes are undiagnosed until...

Page 5: ...eness is highly dependent upon instruction from a person qualified in pain management using TENS If the device treatment becomes ineffective or unpleasant stimulation should be discontinued until re e...

Page 6: ...POSE ALL SUCH WARRANTIES BEING HEREBY EXPRESSLY EXCLUDED The device offers two controllable output channels This device creates electrical impulses whose amplitude duration and modulation can be alter...

Page 7: ...and one program of continuous output Press the Time switch until the desired position is engaged WIDTH The Width dial regulates the width of the pulse for both channels RATE The Rate dial regulates t...

Page 8: ...ter rinse well and blot dry thoroughly Any excess hair should be clipped not shaved to ensure good electrode contact with the skin You may choose to use a skin treatment or preparation that is recomme...

Page 9: ...persist stop treatment and contact your physician or licensed practitioner A 9 volt disposable battery is provided with the unit When the indicator light is dimming the battery has become too weak to...

Page 10: ...the battery If the indicator light is not on when the unit is turned on replace the battery and recheck 2 If the intensity has been adjusted and there is no stimulation check that the lead wires are p...

Page 11: ...nd intensity are adjustable M Modulated Width Pulse width is automatically varied in a six second interval The modulation range of pulse width is from setting value to 35 less than the control setting...

Page 12: ...Distributed by BodyMed Hudson Ohio 44236 1 866 528 2152 Made in Taiwan Reorder Number ZZA250...

Reviews: