Connecting the Device 

(continued)

Battery Information

Changing the Battery

6.  Adjust the Amplitude Control knobs: Locate the Amplitude Control knobs at the top  
 

of the unit. Slowly turn the Amplitude Control knob for Channel 1 clockwise until you  

 

reach the intensity recommended by your physician or licensed practitioner.  

 

Always start with the lowest intensity and increase slowly. 

Repeat the same process  

 

for Channel 2, if appropriate.

If the stimulation levels are uncomfortable or become uncomfortable, reduce the 
stimulation amplitude to a comfortable level. If problems persist, stop treatment and 
contact your physician or licensed practitioner.

A 9-volt disposable battery is provided with the unit. When the indicator light is dimming, 
the battery has become too weak to power the unit and will need to be changed. At this 
point, the unit will shut off until a new battery is inserted.

When the indicator light is dimming, the battery should be replaced with a fresh 9-volt battery.

1.  Remove the slide cover by pressing the top and sliding down until it is completely  
 

removed from the unit. This will reveal the battery compartment.

2.  Remove the old battery from the device.

3.  Place a new battery in the compartment. Note the proper polarity alignment  
 

indicated on the battery and the compartment. 

4.  Make sure to safely dispose of the old battery.

Summary of Contents for ZZA250

Page 1: ...ENGLISH READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE Instruction Manual Transcutaneous Electrical Nerve Stimulator TENS Reorder Number ZZA250...

Page 2: ...Warnings and Precautions 2 About the Device 4 The Device Controls 5 Attaching the Lead Wires 5 Electrode Selection and Care 6 Connecting the Device 6 Battery Information 7 Changing the Battery 7 Clea...

Page 3: ...t 4 Electrodes 1 pack Carrying case 9 Volt battery 2 lead wires Operation manual If you are missing any of these items please contact BodyMed at 1 866 528 2152 before using the unit System Components...

Page 4: ...d by a physician or licensed practitioner CONTRAINDICATIONS Any electrode placement that applies current to the carotid sinus neck region The use of TENS whenever pain syndromes are undiagnosed until...

Page 5: ...eness is highly dependent upon instruction from a person qualified in pain management using TENS If the device treatment becomes ineffective or unpleasant stimulation should be discontinued until re e...

Page 6: ...POSE ALL SUCH WARRANTIES BEING HEREBY EXPRESSLY EXCLUDED The device offers two controllable output channels This device creates electrical impulses whose amplitude duration and modulation can be alter...

Page 7: ...and one program of continuous output Press the Time switch until the desired position is engaged WIDTH The Width dial regulates the width of the pulse for both channels RATE The Rate dial regulates t...

Page 8: ...ter rinse well and blot dry thoroughly Any excess hair should be clipped not shaved to ensure good electrode contact with the skin You may choose to use a skin treatment or preparation that is recomme...

Page 9: ...persist stop treatment and contact your physician or licensed practitioner A 9 volt disposable battery is provided with the unit When the indicator light is dimming the battery has become too weak to...

Page 10: ...the battery If the indicator light is not on when the unit is turned on replace the battery and recheck 2 If the intensity has been adjusted and there is no stimulation check that the lead wires are p...

Page 11: ...nd intensity are adjustable M Modulated Width Pulse width is automatically varied in a six second interval The modulation range of pulse width is from setting value to 35 less than the control setting...

Page 12: ...Distributed by BodyMed Hudson Ohio 44236 1 866 528 2152 Made in Taiwan Reorder Number ZZA250...

Reviews: