  direction of hair growth.

7.  It may be helpful to rub skin lotion on electrode placement area 

   when not wearing electrodes.

8.  Never apply electrodes over irritated or broken skin.

Chapter 13:  APPLICATION OF RE-USABLE SELF 

ADHESIVE ELECTRODES

Application

1.  Clean and dry the skin at the prescribed area thoroughly with  

  soap and water prior to application of electrodes.

2.  Insert the lead wire into the pin connector on the pre-wired  

 electrodes.

3.  Remove the electrodes from the protective liner and apply the  

  electrodes firmly to the treatment site. 

Removal 

1.  Lift at the edge of electrodes and peel;  

  do not pull on the lead wires because  

  it may damage the electrodes.

2.  Place the electrodes on the liner and   

  remove the lead wire by twisting and   

  pulling at the same time.

Care and Storage

1.  Between uses, store the electrodes in the resealed bag in a cool  

  dry place.

2.  It may be helpful to improve repeated application by spreading a  

  few drops of cold water over the adhesive and turn the surface  

  up to air dry. Over saturation with water will reduce the adhesive  

 properties.

Important 

1.  Do not apply to broken skin.

2.  The electrodes should be discarded and re-ordered from your  

  physician when they are no longer adhering.

3.  The electrodes are intended for single patient use only.

4.  If irritation occurs, discontinue use and consult your physician.

5.  Read the instructions for use of self-adhesive electrodes before  

 application.

 

Summary of Contents for ZZAEV820OTC

Page 1: ...ZZAEV820OTC PAIN RELIEF SYSTEM V1 0 Manufactured for BodyMed Hudson Ohio 44236 1 866 528 2152 C M Y CM MY CY CMY K 820 ai 1 2015 5 27 01 30 16 820 ai 1 2015 5 27 01 30 16...

Page 2: ...s 8 9 Lead Wire Maintenance 8 10 Electrode Options 9 11 Electrode Placement 9 12 Tips For Skin Care 9 13 Application Of Re Usable Self Adhesive Electrodes 10 14 Operating Instructions 12 15 Battery In...

Page 3: ...diac pacemaker implanted defibrillators or any other implanted metallic or electronic device Do not use this System if you have undiagnosed chronic pain If you are under the care of a physician consul...

Page 4: ...the removal of electrodes do not use the stimulator again until after the excessive redness has disappeared Turn off the stimulator if the stimulation feels unpleasant or does not provide pain relief...

Page 5: ...QUICK OPERATION GUIDE Your may use the following simple operation steps to operate this System Step 1 Insert the 9 volt battery into your stimulator Step 2 Apply electrode electrodes to the skin Step...

Page 6: ...r quality Follow application procedures outlined in electrode packing to maintain optimal stimu lation and to prevent skin irritation Chapter 11 ELECTRODE PLACEMENT The placement of electrodes can be...

Page 7: ...l on the lead wires because it may damage the electrodes 2 Place the electrodes on the liner and remove the lead wire by twisting and pulling at the same time Care and Storage 1 Between uses store the...

Page 8: ...itch the device off turn the control counter clockwise to the required setting or off position respectively The controls are protected by a cap to avoid unintentional change of intensity 3 Lead Connec...

Page 9: ...o use BATTERY CHARGING 1 Plug the charger into any working 110 or 220 240v mains electrical outlet The use of any attachment not supplied with the charger may result in the risk of fire electric shock...

Page 10: ...output sockets 2 Check the device for defective operating elements Legibility of inscriptions and labels Make sure the inscriptions and labels are not distorted 3 Check the usability of accessories Pa...

Page 11: ...2 With the TIME button pressed turn the unit on 3 Press the UP arrow once to turn the LOCK symbol off 4 Turn unit off 5 Turn the unit on normally it will back to normal function The stimulator has a...

Reviews: