2015/2/2 V1.1+V1.1
27
『
AVERAGE METS =
』
moving words shown first and then show
『
METS= 0.0
』
8. WATT CONTROL MODE
:
Under fitness condition, when WATT value is lower than 25W, program windows
will show figure
『
RPM ↑
』
.
Under fitness condition, when WATT value is more than 400W,program windows
will show figure
『
RPM ↓
』
.
Under fitness condition, if the LEVEL is up to 40 and WATT value can't up to target
value, program windows will show
『
RPM↑
』
.
After fitness mode starting, program will judge the WATT value per 10 seconds.
Under fitness condition, program will contrast the actual WATT value and target
WATT value, the judge method as below:
If target WATT value
:『
actual WATT
≦
target WATT for 75
』
,during fitness and
LEVEL will auto increase 3, the max value can up to LEVEL 40.
If target WATT value
:『
actual WATT
≦
target WATT for 50
』
,during fitness and
LEVEL will auto increase 2, the max value can up to LEVEL 40.
If target WATT value
:
『
actual WATT
≦
target WATT for15
』
,during fitness and LEVEL
will auto increase 1, the max value can up to LEVEL 40.
If target WATT value
:『
actual WATT
≧
target WATT for 15
』
,during fitness and
LEVEL will auto decrease 1, the max value can down to LEVEL 1.
If target WATT value
:『
actual WATT
≧
target WATT for 50
』
,during fitness and
LEVEL will auto decrease 2, the max value can down to LEVEL 1.
If target WATT value
:『
actual WATT
≧
target WATT for 75
』
,during fitness and
LEVEL will auto decrease 3, the max value can down to LEVEL 1.
4.4.7. GOAL MODE
:
it is clockwise mode
1. Under start/steady windows, press GOAL key can enter MANUAL MODE clockwise
mode, data windows moves left and show words
『
1.TIME 2.DISTANCE