background image

S

afety Instructions 

 

 

 

Important safety notes

 

Concerning symbols used on the extraction unit and referred 
to within this manual. 

 

Danger 
 

Refers to an immediately impending danger. If the danger is 
not avoided, it could result in death or severe (crippling) 
injury. Please consult the manual when this symbol is 
displayed. 

Warning 

 
Refers to a possibly dangerous situation. If not avoided it 
could result in death or severe injury. Please consult the 
manual when this symbol is displayed. 

Caution 
 

Refers to a possibly harmful situation. If not avoided, 
damage could be caused to the product or something in its 
environment. 

  
Important (Refer to manual) 
 

Refers to handling tip and other particularly useful 
information. This does not signify a dangerous or harmful 
situation. Refer to manual when this symbol is displayed. 
 

Electrical Safety 

The V600 has been designed to meet the safety 
requirements of the Low Voltage Directive 2006/95/EC 
(previously numbered 73/23/EEC) 

Warning 

When working with the pump/motor housing open, Live 
230/115 volt mains components are accessible. Ensure that 
the rules and regulations for work on live components are 
always observed.

 

 

 

Important 

To reduce the risk of fire, electric shock or injury: 

1.

 

Always isolate the system from the mains power 
supply before removing the pump/motor access 
panel. 

2.

 

Use only as described in this manual. 

3.

 

Connect the system to a properly grounded outlet. 

 
Dangers to eyes, breathing and skin 

Once used, the filters within the V600 system may contain a 
mixture of particulates, some of which may be sub-micron 
size. When the used filters are moved it may agitate some of 
this particulate, which could get into the breathing zone and 
eyes of the operative. Additionally, depending on the 
materials being processed, the particulate may be an irritant 
to the skin.  
 

Caution: When changing used filters always wear a mask, 
safety shoes, goggles and gloves.

 

 

Carbon selection 

Please note that the media within the filter fitted in the 
V600 is capable of adsorbing a wide range of organic 
compounds. However, it is the responsibility of the user to 
ensure it is suitable for the particular application it is being 
used on.  

BOFA Technical Service 

If problems arises with your V600 unit or if it displays a fault 
code, please contact us:  

 

Visit our website at www.bofa.co.uk for on-line help. 

 

Or contact the helpline on 

+44 (0) 1202 699444

Mon-Fri, 9am-5pm. 
Email: Technical@bofa.co.uk 

Serial Number 

For future reference, fill in your system details in the space 
provided. The serial number is on the rating label located on 
the side/rear of the unit.  
Serial Number: 

 

 

 

 

01 

Summary of Contents for V600

Page 1: ...V600 Issue 2 Jan 2017 ...

Page 2: ......

Page 3: ...Overview 01 Control Panel Feet Clips Handles ...

Page 4: ...Overview 02 Air Inlet Mains Inlet Signal Cable Inlet Air Outlet Mains Isolation Switch Motor Cooling Override Switch ...

Page 5: ...Overview Flow Adjustment 03 Company Branding Filter Blocked Filter 75 full System Running Clean VOC Alarm ...

Page 6: ...c shock or injury 1 Always isolate the system from the mains power supply before removing the pump motor access panel 2 Use only as described in this manual 3 Connect the system to a properly grounded outlet Dangers to eyes breathing and skin Once used the filters within the V600 system may contain a mixture of particulates some of which may be sub micron size When the used filters are moved it ma...

Page 7: ...e Relevant approval markings logos PLEASE NOTE If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment maybe compromised Fire Risk Warning In the very rare event that a burning ember or spark is drawn into the fume extraction unit it may be possible that the filters will ignite Whilst any resultant fire would typically be retained within the ...

Page 8: ...500 mm space is available around any vented panels on the extractor to ensure adequate airflow 2 Check the filter is located in its correct position before replacing the lid and securing the clips Caution Due to the weight of the extractor suitable lifting equipment should be used and with regard to appropriate safety precautions See Appendix for product weight details Caution Do not block or cove...

Page 9: ...rm Nozzle Extraction The stay put arm should be mounted as close as possible to the marking point using the horseshoe clips Unscrew the push fit connector from the other side of the flexible hose Cut the flexible hose to suit the distance back to the extractor connection and push onto the extractor inlet Purge air should be kept to a minimum where possible to prevent the fume being blown away from...

Page 10: ...tion is made as additional connections may be required before power is connected to the extractor Connect the power cable to an isolated electrical supply The mains socket should be installed near the extractor it should be easily accessible and able to be switched On Off The cable run should be arranged so as not to create a trip hazard Cabinets Cabinets normally have a 75mm 0r 100mm spigot for f...

Page 11: ...either DC voltage input or the Volt free input The override feature can be toggled On Off by a switch mounted on the internal motor access panel see below for switch location Switch in On position In this position the extractor will require a start signal either Voltage input or Volt free depending on the requested specification to enable the motor within the extraction unit Switch in Off position...

Page 12: ...ally blocked filters The extractor and all pipe work must be fully installed and connected before the airflow is set To set the airflow Press the Up arrow button to increase airflow and press the down arrow button to decrease airflow The level of airflow is indicated by the vertical row of six blue LEDs to the right of the mains isolation switch As the airflow increases more blue LEDs light up and...

Page 13: ...lter changes should be maintained by the user The filters require attention when the display shows the configuration shown on the next page or when the extractor no longer removes fume efficiently It is recommended that a spare set of filters are kept on site to avoid prolonged unit unavailability Part numbers for replacement filters can be found on the filters fitted in your system To prevent ove...

Page 14: ...olate the electrical supply to the extractor 2 Undo the two clips on the sides of the unit and remove the motor section using the two handles on the sides of the lid 3 Lift the filter out of the unit Once removed it is recommend that the used filters are bagged and sealed 4 Lower the new filter into position If the current pre filter is found to be serviceable place into the new combined filter 5 ...

Page 15: ...Combined Filter Date Engineer Filter disposal The V600 combined filter is manufactured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method of disposal of the used filters depends on the material deposited on them For your guidance Deposit EWC Listing Comment Non Hazardous 15 02 03 Can be disposed of as non hazardous waste Hazardous 15 02 02M The t...

Page 16: ...l operating speed Size Metric mm Imperial inches Height 590 23 1 Depth 458 18 Width 396 15 6 Filters Filter Type Surface area Efficiency Pre Filter F8 4 2m2 95 0 9 microns HEPA Filter Combined filter 2 1 m2 99 997 0 3µ Filter Type Carbon Type Amount Carbon filter combined filter Activated Carbon 8 5kgs Environmental operating range Temperature 5o C to 40o C Humidity Max 80 RH up to 31o C Max 50 RH...

Page 17: ...Information BOFA Headquarters 21 22 Balena Close Creekmoor industrial Estate Poole Dorset BH17 7DX UK Phone 44 0 1202 699444 BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 001 618 205 5007 ...

Reviews: