afety Instructions

 

 

 

 

 

 

 
Warning and Information labels 

The following listing details labels used on your V600 unit. 
 

Goggles, Gloves & Mask Label 

 
 
 

 

Location: Front face of filter. 
Meaning: Goggles, Gloves and Masks should be worn while 
handling used filters. 
 

Do Not Cover Label

 

 
 
 
 

Location: Rear Exhaust Box 
Meaning: Do not cover any louvers or holes adjacent to the 
label. 
 

Electrical Danger 

 
 
 

 

Location: Electrical access panel, top half of unit. 
Meaning: Removal of panels with this label attached will 
allow access to potentially live components. 
 

Warning Label 

 

Location: Next to release clips. 
Meaning: Power should be isolated before the panel with 
this label attached is opened/ removed. 
 
 
 
 

 

 
Serial Number Label 

 

Location:  right face of unit, top right corner. 
Meaning: This label contains a variety of information about 
the extraction unit, including.   
 

 

Company name, Address & Contact number 

 

Extractor model 

 

Unit serial number 

 

Operating voltage range 

 

Maximum current load 

 

Operating frequency 

 

Year of Manufacture 

 

Relevant approval markings/ logos 
 

PLEASE NOTE: 

If the equipment is used in a manner not 

specified by the manufacturer, the protection provided by 
the equipment maybe compromised. 

Fire Risk Warning 

In the very rare event that a burning ember or spark is drawn 
into the fume extraction unit, it may be possible that the 
filters will ignite. Whilst any resultant fire would typically be 
retained within the fume extraction unit, the damage to the 

extractor 

could

 be significant. 

It is therefore essential to minimise the possibility of this 
occurring by undertaking an appropriate Risk assessment to 
determine:- 

a). Whether additional fire protection equipment should be 
installed.  

b). Appropriate maintenance procedures to prevent the risk 
of build-up of debris which could potentially combust. 

This unit should not be used on processes where sparks 
could occur, with explosive dusts and gases, or with 
particulates which can be pyrophoric (can spontaneously 
ignite), without implementation of additional precautions 

It is essential that nozzles or other extraction/ fume capture 
devices and hoses/pipework are cleaned regularly to prevent 
the build-up of potentially ignitable debris 

 

02 

02 

Summary of Contents for V600

Page 1: ...V600 Issue 2 Jan 2017 ...

Page 2: ......

Page 3: ...Overview 01 Control Panel Feet Clips Handles ...

Page 4: ...Overview 02 Air Inlet Mains Inlet Signal Cable Inlet Air Outlet Mains Isolation Switch Motor Cooling Override Switch ...

Page 5: ...Overview Flow Adjustment 03 Company Branding Filter Blocked Filter 75 full System Running Clean VOC Alarm ...

Page 6: ...c shock or injury 1 Always isolate the system from the mains power supply before removing the pump motor access panel 2 Use only as described in this manual 3 Connect the system to a properly grounded outlet Dangers to eyes breathing and skin Once used the filters within the V600 system may contain a mixture of particulates some of which may be sub micron size When the used filters are moved it ma...

Page 7: ...e Relevant approval markings logos PLEASE NOTE If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment maybe compromised Fire Risk Warning In the very rare event that a burning ember or spark is drawn into the fume extraction unit it may be possible that the filters will ignite Whilst any resultant fire would typically be retained within the ...

Page 8: ...500 mm space is available around any vented panels on the extractor to ensure adequate airflow 2 Check the filter is located in its correct position before replacing the lid and securing the clips Caution Due to the weight of the extractor suitable lifting equipment should be used and with regard to appropriate safety precautions See Appendix for product weight details Caution Do not block or cove...

Page 9: ...rm Nozzle Extraction The stay put arm should be mounted as close as possible to the marking point using the horseshoe clips Unscrew the push fit connector from the other side of the flexible hose Cut the flexible hose to suit the distance back to the extractor connection and push onto the extractor inlet Purge air should be kept to a minimum where possible to prevent the fume being blown away from...

Page 10: ...tion is made as additional connections may be required before power is connected to the extractor Connect the power cable to an isolated electrical supply The mains socket should be installed near the extractor it should be easily accessible and able to be switched On Off The cable run should be arranged so as not to create a trip hazard Cabinets Cabinets normally have a 75mm 0r 100mm spigot for f...

Page 11: ...either DC voltage input or the Volt free input The override feature can be toggled On Off by a switch mounted on the internal motor access panel see below for switch location Switch in On position In this position the extractor will require a start signal either Voltage input or Volt free depending on the requested specification to enable the motor within the extraction unit Switch in Off position...

Page 12: ...ally blocked filters The extractor and all pipe work must be fully installed and connected before the airflow is set To set the airflow Press the Up arrow button to increase airflow and press the down arrow button to decrease airflow The level of airflow is indicated by the vertical row of six blue LEDs to the right of the mains isolation switch As the airflow increases more blue LEDs light up and...

Page 13: ...lter changes should be maintained by the user The filters require attention when the display shows the configuration shown on the next page or when the extractor no longer removes fume efficiently It is recommended that a spare set of filters are kept on site to avoid prolonged unit unavailability Part numbers for replacement filters can be found on the filters fitted in your system To prevent ove...

Page 14: ...olate the electrical supply to the extractor 2 Undo the two clips on the sides of the unit and remove the motor section using the two handles on the sides of the lid 3 Lift the filter out of the unit Once removed it is recommend that the used filters are bagged and sealed 4 Lower the new filter into position If the current pre filter is found to be serviceable place into the new combined filter 5 ...

Page 15: ...Combined Filter Date Engineer Filter disposal The V600 combined filter is manufactured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method of disposal of the used filters depends on the material deposited on them For your guidance Deposit EWC Listing Comment Non Hazardous 15 02 03 Can be disposed of as non hazardous waste Hazardous 15 02 02M The t...

Page 16: ...l operating speed Size Metric mm Imperial inches Height 590 23 1 Depth 458 18 Width 396 15 6 Filters Filter Type Surface area Efficiency Pre Filter F8 4 2m2 95 0 9 microns HEPA Filter Combined filter 2 1 m2 99 997 0 3µ Filter Type Carbon Type Amount Carbon filter combined filter Activated Carbon 8 5kgs Environmental operating range Temperature 5o C to 40o C Humidity Max 80 RH up to 31o C Max 50 RH...

Page 17: ...Information BOFA Headquarters 21 22 Balena Close Creekmoor industrial Estate Poole Dorset BH17 7DX UK Phone 44 0 1202 699444 BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 001 618 205 5007 ...