Page 5
General
1.1
General safety instructions
3. Prior to maintenance or repair work:
–
Switch off the compressor using the OFF button.
–
Actuate emergency-stop switch/button.
–
Open mains disconnecting device.
–
Secure mains disconnecting device by means of lock out tag out.
–
Fix a warning label to the control and fill in the name of the person re-
sponsible who is authorized to switch on the maschine again.
–
Check to ensure that all parts are currentless.
–
Cover or block off adjacent energised parts.
–
Prior to starting work let cool down all hot components of the compres-
sor to 122°F.
–
Disconnect the compressor from the compressed air network (relieve
or block pressurized lines).
4. Exercise extreme caution during repair or maintenance work requiring the
compressor to be operational. Ensure that persons keep out of reach of
the hazardous area.
5. Ensure that work on the electrical equipment is only executed by qualified
electricians.
6. Work on parts and devices under current is prohibited. Exceptions are gov-
erned by the appropriate regulations.
7. Prior to starting work on the electrical system the power supply has to be
switched off and secured against unintentional switching on again. Imme-
diately after having finished the work all dismantled claddings and safety
devices must be refitted.
8. The operator is responsible to check the compressor daily for externally
visible damage and defects, and to immediately report any changes (in-
cluding operational behaviour).
9. When the automatic restart (Auto-Restart) is activated, the compressor will
start automatically following a voltage loss. Prerequisite: The net pressure
is lower than the set switch-on pressure.
Accident prevention
regulations
The owner of a compressor plant is responsible to ensure that it is properly
installed, operated and maintained.
For operation of the compressor plant outside the Federal Republic of Ger-
many, the accident prevention regulations of the country, where the compres-
sor is operated, must be observed in addition to the data contained in these
operating instructions. In the event that measures are required above and
beyond the legal regulations specified in the Federal Republic of Germany or
the data contained in these operating instructions, then it is of utmost impor-
tance that these be carried out prior to commissioning the compressor plant.