Maintenance
6.2
General
Page 48
BOGE Operating instructions for C 15 series screw compressors
General information
concerning the
lubricants used
We recommend using only oil according to following specification:
–
Viscosity range of 55 cSt at 104°F.
–
Minimum viscosity at 212°F of 8 cSt.
–
Maximum viscosity at 32°F of 1000 cSt.
–
(FZG A/8.3/90 min 10).
–
Excellent oxidation stability: Meets requirements of Pneurop oxidation test.
–
Antifoam – additives.
–
Additives to prevent residue formation.
–
Compatibility with all used sealing materials like Neoprene, FPM, PTFE,
FKM (Viton) and acrylic and epoxy resin paints.
–
Flash point > 446°F.
–
Additives for excellent demulsifying properties.
–
Additives for corrosion protection of metallic surfaces.
–
Excellent oxidation stability: Rotating bomb oxidation Test (ASTM D 2272)
higher than 2400 minutes.
–
Meets VDL requirements DIN 51 506 for lube oils (including Pneurop test).
–
Or you use BOGE compressor oil
Syprem 8000 S
. The stated mainte-
nance intervals refer to the use of
Syprem 8000 S
only.
–
Syprem 8000 S
can be purchased from BOGE retailers.
–
Never mix different oil types and brands.
The additives may be incompatible. It may lead to foam formation, prema-
ture aging or loss of lubricating ability.
WARNING: Risk of injury!
Oil presents a potential danger to health and environment due to their addi-
tives.
–
Avoid contact with skin and eyes.
Wear protective gloves made of resistant synthetic material.
Wash yourself thoroughly after contact with oils.
–
Do not inhale the fumes or mist.
–
Protect your environment.
Ensure that no oil is spilt.
–
Fire, naked flames and smoking is strictly prohibited when handling oil.
Please take notice of the directions in the corresponding safety data sheet!