Maintenance
6.3
Maintenance work compressor
Page 50
BOGE Operating instructions for C 15 series screw compressors
6.3 Maintenance work compressor
Cleaning or changing
suction filter
Cleaning:
–
1x monthly,however, at least every 500 operating hours.
–
Correspondingly earlier if the air taken in is heavily soiled.
Change:
–
In the event of damage.
–
After the second cleaning.
Switch off the compressor with the OFF button.
Fig. 6.2: Changing the intake filter
Cleaning the filter
cartridge
WARNING: Risk of injury!
Prior to any maintenance and servicing work take all necessary safety pre-
cautions described on page 44!
Removing the filter car-
tridge
–
Open safety sound insu-
lation hood.
–
Unscrew lid (1) of filter
housing in the direction
of the arrow.
–
Take out filter insert.
WARNING!
Do not clean filter cartridges in liquids.
Do not use hard objects for cleaning in order that the filter paper is not dam-
aged.
Replace the filter cartridge if it is damaged or has been cleaned twice.
–
Tap the filter cartridge with your hand to knock out coarse dust.
–
Blow out fine dust (max. pressure 73 psig)
from the inside to the out-
side
.
–
Clean the sealing surfaces of the filter cartridge.