Maintenance
6.3
Maintenance work compressor
Page 54
BOGE Operating instructions for C 15 series screw compressors
Checking the oil level,
topping up oil
Check:
–
Prior to commissioning/start-up of the compressor.
–
After that every month.
Topping up:
–
If the oil level has dropped to a level 0.39 – 0.79 inch below the bottom
edge of the thread.
–
Switch off the compressor using the OFF button.
–
Close ball valve at the compressed air outlet.
–
Vent the compressor (as described in the beginning of the chapter).
–
Wait approx. 3 minutes to permit the oil to settle.
Fig. 6.5: Checking the oil level, topping up with oil
WARNING!
Always use the same oil type when topping up. Never mix different oil types
and brands.
WARNING: Risk of injury!
Prior to any maintenance and servicing work take all necessary safety pre-
cautions described on page 44!
WARNING: Risk of injury!
Danger of burning due to hot oil!
Always wear safety gloves!
–
Remove plug (2) from oil fill-
ing socket (1).
–
Check oil level.
The oil level must not drop
to a level more than
0.79 inch below the bottom
edge of the thread.
–
If necessary, top up with oil
to the lower edge of the
thread ("max." mark) on the
oil filling socket.
–
Screw plug (2) back in.
–
Open the ball valve at the
compressed air outlet.